AMT/PTD/PBX/0058/4/6/EN
Installation and Maintenance Manual - Aastra 5000
Page
434 01/2011
Maintenance
SHEET E-10
REPLACING AN IUCV-D CARD
AVAILABILITY
•
Partial mission capable
OPERATORS (s)
•
1 operator on site
DURATION
•
2 minutes
INGRÉDIENT(S)/CONSOMMABLE(S)
•
N/A
Table 17:
OPERATION
DETAILS OF THE OPERATION / COMMENTS
•
Back up the customer
configuration.
•
Precautionary operation to be carried out if there is no existing
copy (which is the case when previous installation operations
have been carried out and the procedures followed).
•
Refer to [1]
•
In the case of remote operation, contact the remote operator
before starting any operation.
•
Disable the IUCV-D card
from the AMP.
Refer to the document AMP Operating manual.
•
Disconnect the cables.
•
Disconnect the external cables from the card and mark the
cables for refitting.
•
Pull out the card from its
slot.
•
Use the 1/4 turn locks to remove the card from its slot
(see Figure 4.1.
Nota : The IUCV-D card can be removed from an
operational AXD iPBX.
Nota : The i-button becomes inaccessible when the IUCV-
D card is removed. The locking software checks
every hour whether the i-button module is available.
If the software makes this check while the IUCV-D
is being replaced, some functions will be locked
dynamically (the directory, for instance). Simple call
(also for IP sets) remain operational.
•
Recover the i-button
module.
•
Recover, on the IUCV-D card, the i-button module containing the
system's identifier.
Summary of Contents for AXD
Page 16: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 16 01 2011...
Page 20: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 20 01 2011...
Page 22: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 22 01 2011...
Page 26: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 26 01 2011...