AMT/PTD/PBX/0058/4/6/EN
Installation and Maintenance Manual - Aastra 5000
Page
420 01/2011
Maintenance
SHEET E-6
REPLACING FUSES IN THE POWER SUPPLY MODULE (AXD IPBX)
AVAILABILITY
•
No mission capable if power supply module is not duplicated
•
Full mission capable if power supply module is duplicated
OPERATORS (s)
•
1 operator on site
DURATION
•
1 minute 30 seconds
•
1 multimeter
INGRÉDIENT(S)/CONSOMMABLE(S)
•
N/A
Table 9:
OPERATION
DETAILS OF THE OPERATION / COMMENTS
•
Alert the operator.
•
In the case of remote operation, contact the remote operator
before starting any operation.
•
Power off the power
supply module.
•
Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
Avertissement :
For a duplex configuration,
when a power supply module is out of service, the operator
has approximately 90 seconds to replace and power on
again the power supply module. After 90 seconds, the
second power supply module is automatically powered off.
•
"I/O" switch to "O".
•
In a simplex configuration, if it is an iPBX with multiple cabinets,
power off the power supply module of the main cabinet then
those of the expansion cabinets.
•
Disconnect the mains
cable.
•
Disconnect the mains cable on the front panel of the power
supply module.
Summary of Contents for AXD
Page 16: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 16 01 2011...
Page 20: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 20 01 2011...
Page 22: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 22 01 2011...
Page 26: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 26 01 2011...