User allocation
Each terminal is allocated to a user in the configuration. If a terminal has been cre-
ated at the connected port and the address selection switch is correctly selected
but no user is allocated to the terminal, the terminal display reads
No Number
and
indicates the terminal ID. In this state the terminal is not ready for operation.
Terminal type
The terminal type is specified along with the configuration of the system. when the
lines are also assigned to the line keys.
Note:
If the terminal type configured is incorrect, the terminal display shows
the warning
Wrong terminal type
. On the Office 10 the LED flashes slowly.
In this situation, although the terminal can be used for basic telephone
operations, none of the added features will be available. The terminal
type must be entered via the AIMS Configuration Manager or on the ter-
minal via login to the PBX.
Carrying out a logon on the terminal:
– Office 10: Press the Foxkey twice.
– All other system terminals: Long keypress (long click) on a function
key.
Log on new set
appears next. Confirm with Foxkey
Yes
.
Self-tests for AD2 terminals
Once the terminal has been checked with regard to connections, unlocking, etc.,
the self-test can be used to detect possible sources of error.