Configuring the application card

15

Applications Card CPU2

syd-0421/1.2 – R2.1 – 07.2012

Configuring applications 

Configure the mandatory applications. The hyperlinks at the bottom of the 

Configuration

 screen take you to the OIP and TWP configuration platforms.  Log on 

using the username 

cpu2-emmc

 and the application card password.

Saving the configuration (menu 

Maintenance

)

You can create a configuration data backup under 

Maintenance

. For this, click 

Create backup

. Backup data is then respectively created for the OIP and TWP 

configuration data then stored in the data system of the application card and listed 
on the screen.  The file names contain date and time-related information.

You can copy backup data to your data storage device with the 

Download

 function. 

With the 

Restore

 function, restore a specific backup from the application card's file 

system and activate the configuration data contained therein.  

You can delete a backup file from the application card  file system, with the 

Delete

 

function.

In 

Upload backup file

 you can choose from  your data storage device a backup file 

which you wish to reload on the application card file system.  Click above the 

Upload backup file

 button to take the action. 

Installing client applications

To install client applications on user workstations, change to the 

Client Roll-out

 

screen and click 

MailTo

 on the client application to be installed. An e-mail is 

opened with the installation link. Send the e-mail to the user group you want and 
ask it to start the installation via the installation link.

Summary of Contents for 470

Page 1: ...Installation Guide Platforms supported Aastra 470 These intructions take you through the installation and initial configuration of the Aastra 470 communication server applications card Innovations wit...

Page 2: ...a 9 Installing the application card 10 Configuring the application card 13 Configuring the fax server 16 Updating system software 20 Replacing an application card 21 Content Orange Power supply turned...

Page 3: ...terface for application developers and a multitude of expansion cards and modules The business communication solution with all its elements was designed to cover the full spectrum of communication req...

Page 4: ...uestion Exclusion of Liability All parts and components of the Aastra 400 communication solution are manufactured in accordance with ISO 9001 quality guidelines The relevant user information has been...

Page 5: ...ery is complete and undamaged Notify your supplier immediately of any defects do not install or put into operation any components that may be defective Check that you have all the relevant user docume...

Page 6: ...efects and malfunctions in accordance with Aastra s authorized written functional specification relating to such products during a one 1 year period from the date of original purchase Warranty Period...

Page 7: ...ht conferred by such a provision or any liability of Aastra in relation to a failure to comply with a guarantee that applies under Division 1 of Part 3 2 of the ACL to a supply of goods or services Th...

Page 8: ...resupply of the services or ii the payment of the cost of resupply and b in the case of goods i the replacement of the goods or the supply of equivalent goods or ii the repair of the goods or iii the...

Page 9: ...entele includes acknowledged telephone and data network operators in North America Europe and Africa as well as Internet Service Providers and distributors of renown Aastra Technologies Limited TSX AA...

Page 10: ...server 6 Check the communication server IP environment with regard to the following Note There should be no other communication server with installed application card on the communication server subne...

Page 11: ...essing the On Off pushbutton on the card 6 Starting the application card is similar to starting a computer and may take a while The On Off pushbutton LED turns green after the booting process and indi...

Page 12: ...file 5 Click Apply to upload the licence data and exit the setup wizard Licence data upload might take a while The application card applications are now upgraded and ready for configuration Note The n...

Page 13: ...erver IP address If the wrong IP address is entered the setup wizard has probably detected othercommunication servers on your subnet Youcansee allthe IP addresses of detected communication servers und...

Page 14: ...free Click Refresh to refresh the display Note Check whether you have assigned each user the required CTI applications in the communication server user configuration Parameter Explanation Device Name...

Page 15: ...nformation You can copy backup data to your data storage device with the Download function With the Restore function restore a specific backup from the application card s file system and activate the...

Page 16: ...ser Use of the fax service is subject to fax licences Fax server settings Parameter Explanation IP address and port display only The fax service IP address is identical to the applications card IP add...

Page 17: ...ccess prefix and not incanonical format Example Prefix 0 is the default value for most European countries You enter a route prefix The prefix is added to the destination number and the routing takes p...

Page 18: ...ting 4 Check that the settings for the DDI interpretation are correct Configuration Routing Trunk group view Base number setting and DDI prefix setting 5 Check the user settings to make sure an e mail...

Page 19: ...communication server via an analogue network interface proceed as follows 1 Follow the above instructions step by step 2 2 Assign the fax server as routing destination for the fax trunk group Configu...

Page 20: ...e 15 2 Copy the ZIP file with the new version of the system software onto a USB stick and plug the USB stick into one of the USB sockets on the applications card Note Make sure the ZIP file is not loc...

Page 21: ...ation server and remove the application card 3 Switch on the communication server 4 From your administration PC open your communication server s WebAdmin and log on 5 Navigate up to the card window Co...

Page 22: ...instructions 5 Installing client applications 15 Installing the application card 10 IP network configuration 14 L Licensing 14 Limited Warranty Australia only 6 Listenansicht 8 O OIP password 15 OIP...

Reviews: