![background image](http://html.mh-extra.com/html/aandd/winct-plus/winct-plus_instruction-manual_446567023.webp)
22
-COM
For COM connection, select this option button.
Setup the RS232C communication settings.
Port:Com: Com port (*1 to 32)
Baud Rate: Baud rate (600, 1200, *2400, 4800, 9600, 14400, 19200, 28800)
Parity: Parity (*E: even number, O: odd number, N: None)
Length: Data length (*7, 8)
Stop Bit: Stop bit (*1, 1.5, 2)
Decimal Point
Sets the decimal point- *dot (.), comma (,)
Separator
Sets the pause to be inserted at the end of data entered in the table.
The data will be separated using the selected character.
When “Unit” is selected, data will be separated when a character is received after a number.
You can set a character in the Set1 or Set2.
*Unit, *Comma, Space, Tab, Set1, Set2
Data Format
Sets data to store other than received data.
Data, *Time
Interval
Collects data received only in every setup time into the computer.
This button is used when data processing speed of the computer is slow, or the data is entered
periodically.
The time can be set to the second. The default setting is 0 sec.
When it is set at 0 sec, all the data will be sent to the application.
Test button
Sends the set command. If the data from the weighing instrument is displayed, the
communication is normally made.
The example of the pause by Separator will be displayed.
OK button
Saves the changed settings.
Cancel