background image

 

7

 

Using the Monitor 

Selecting The Correct Cuff 

 Using 

the 

correct 

cuff size is important for an accurate reading. If the cuff is not the 

proper size, the reading may yield an incorrect blood pressure value.   

  The arm size is printed on each cuff. 

 The 

index

 

 

and proper fit range, on the cuff, tell you if you are applying the correct 

cuff. (Refer to "

Applying The Arm Cuff

" on next page) 

 If the index

 

 

points outside of the range, contact your local dealer to purchase a 

replacement cuff. 

  The arm cuff is a consumable. If it becomes worn, purchase a new one. 

 

Arm Size 

Recommended Cuff Size 

Catalog Number 

32 cm to 45 cm 

Large adult cuff 

CUF-D-LA 

22 cm to 32 cm 

Adult cuff 

CUF-D-A 

 Arm 

size: 

The 

circumference at the biceps. 

 

Note:  Model UA-621 is not designed for using a small adult cuff.

 

 

Symbols printed on the cuff. 

Symbols 

Function / Meaning 

Recommended Action 

 

Artery position mark 

Set the

 

 

mark on the artery of the 

upper arm or in line with the ring 

finger on the inside of the arm. 

 

Index 

 

REF  Catalog number 

 

 

Proper fit range for the adult cuff. 

It's printed on the adult cuff. 

 

 

Range to use the large

 

adult cuff. 

Over range printed on the adult cuff. 

Use the large adult cuff instead of 

the adult cuff. 

 

Proper fit range for the large

 

adult cuff.

It's printed on the large adult cuff. 

 

  Under range printed on the adult cuff.

 

 

Range to use the

 

adult cuff. 

It's printed on the large

 

adult cuff. 

Use the adult cuff instead of the 

large adult cuff.   

  Lot number 

 

 

 

Large adult cuff 

 

 

Adult cuff 

Proper fit range

Proper fit range

Summary of Contents for UA-621

Page 1: ...Digital Blood Pressure Monitor Model UA 621 Instruction Manual 1WMPD4001898D...

Page 2: ...ring Data 11 What Is An Irregular Heartbeat 12 Pressure Bar Indicator 12 WHO Classification Indicator 12 About Blood Pressure 13 What Is Blood Pressure 13 What Is Hypertension And How Is It Controlled...

Page 3: ...es X ray or other devices with strong electrical fields Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulat...

Page 4: ...pressure oxygen chamber or an oxygen tent It may cause a fire or explosion Parts Identification Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Battery Indicator I H B...

Page 5: ...ry The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Page 6: ...ory automatically 2 Recalling Data Refer to page 11 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are...

Page 7: ...ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Remo...

Page 8: ...cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 621 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action A...

Page 9: ...ent Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest before taking the mea...

Page 10: ...p inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse...

Page 11: ...tional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure v...

Page 12: ...1 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed 2 The data are automatically displayed...

Page 13: ...Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator...

Page 14: ...uce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can p...

Page 15: ...batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measure...

Page 16: ...Type UA 621 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Number of measurements Approximat...

Page 17: ...33C Input 100 240V Output 6V 500mA TB 233BF Input 240V Output 6V 500mA Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C TB...

Page 18: ...ingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 6...

Reviews: