background image

 

9

 

Measurements 

 

Model UA-621 is designed to detect the pulse and to inflate the cuff to a systolic 

pressure level automatically. 

 

If your systolic pressure is expected to exceed 230 mmHg, read   

"Measurement With The Desired Systolic Pressure" on the next page. 

 

Normal Measurement 

1.  Place the cuff on the arm (preferably the left arm). 

  Sit quietly during measurement. 

 

2. Press the 

 START 

 button. 

  The average blood pressures and last data 

number are displayed briefly.   

Then the display changes, as indicated in the 

figure at the right, as the measurement 

begins. The cuff starts to inflate. It is normal 

for the cuff to feel very tight. A pressure bar 

indicator is displayed, as in the figure at the 

right, during inflation. 

 

Note: If you wish to stop inflation at any time, 

press the 

 START 

 button again. 

 

3. When inflation is complete, deflation starts 

automatically and the 

  (heart mark) blinks, 

indicating that the measurement is in 

progress. Once the pulse is detected, the 

mark blinks with each pulse beat. 

 

Note: If an appropriate pressure is not obtained, 

the device starts to inflate again 

automatically. 

 

4. When the measurement is complete, the 

systolic and diastolic pressure readings and 

pulse rate are displayed. The cuff exhausts 

the remaining air and deflates completely. 

 

5. Press the 

 START 

 button again to turn off 

the power. 

 

Note: Model UA-621 is provided with an automatic 

power shut-off function. Allow at least three 

minutes between measurements on the same 

person. 

At heart level 

Starts inflation

Pressurizing

Measurement 

in progress

Systolic pressure 

Diastolic pressure 

WHO classification 

 Pulse 

rate 

Exhausts remaining 

air automatically 

 

 START 

 button 

Averaged data 

Data number 

Summary of Contents for UA-621

Page 1: ...Digital Blood Pressure Monitor Model UA 621 Instruction Manual 1WMPD4001898D...

Page 2: ...ring Data 11 What Is An Irregular Heartbeat 12 Pressure Bar Indicator 12 WHO Classification Indicator 12 About Blood Pressure 13 What Is Blood Pressure 13 What Is Hypertension And How Is It Controlled...

Page 3: ...es X ray or other devices with strong electrical fields Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulat...

Page 4: ...pressure oxygen chamber or an oxygen tent It may cause a fire or explosion Parts Identification Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Battery Indicator I H B...

Page 5: ...ry The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Page 6: ...ory automatically 2 Recalling Data Refer to page 11 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are...

Page 7: ...ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Remo...

Page 8: ...cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 621 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action A...

Page 9: ...ent Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest before taking the mea...

Page 10: ...p inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse...

Page 11: ...tional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure v...

Page 12: ...1 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed 2 The data are automatically displayed...

Page 13: ...Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator...

Page 14: ...uce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can p...

Page 15: ...batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measure...

Page 16: ...Type UA 621 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Number of measurements Approximat...

Page 17: ...33C Input 100 240V Output 6V 500mA TB 233BF Input 240V Output 6V 500mA Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C TB...

Page 18: ...ingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 6...

Reviews: