Preliminary Remarks 

  This device conforms to the European Directive 93/42 EEC for Medical Products. 

This is made evident by the 

  mark of conformity.   

(0366: The reference number to the involved notified body). 

  The device is designed for use on adults only, not newborns or infants. 

  Environment for use. The device is for use indoors. 

 

This device is designed to measure blood pressure and pulse rate of people for 

diagnosis. 

 
 

Precautions 

 Precision components are used in the construction of this device. Extremes in 

temperature, humidity, direct sunlight, shock or dust should be avoided. 

  Clean the device and cuff with a dry, soft cloth or a cloth dampened with water 

and a neutral detergent. Never use alcohol, benzene, thinner or other harsh 

chemicals to clean the device or cuff. 

  Avoid tightly folding the cuff or storing the hose tightly twisted for long periods, as 

such treatment may shorten the life of the components. 

  The device and cuff are not water resistant. Prevent rain, sweat and water from 

soiling the device and cuff. 

  Measurements may be distorted if the device is used close to televisions, 

microwave ovens, cellular telephones, X-ray or other devices with strong 

electrical fields. 

  Used equipment, parts and batteries are not treated as ordinary household waste, 

and must be disposed of according to the applicable local regulations. 

  When the AC adapter is used, make sure that the AC adapter can be readily 

removed from the electrical outlet when necessary. 

 

When reusing the device, confirm that the device is clean. 

 

Do not modify the device. It may cause accidents or damage to the device. 

 

To measure blood pressure, the arm must be squeezed by the cuff hard enough 

to temporarily stop blood flow through the artery. This may cause pain, numbness 

or a temporary red mark to the arm. This condition will appear especially when 

measurement is repeated successively. Any pain, numbness, or red marks will 

disappear with time. 

Contraindications 

The following are precautions for proper use of the device. 

  Do not apply the cuff on an arm with another medical electrical equipment attached. 

The equipment may not function properly. 

 

People who have a severe circulatory deficit in the arm must consult a doctor 

before using the device, to avoid medical problems. 

 

Do not self-diagnose the measurement results and start treatment by yourself. 

Always consult your doctor for evaluation of the results and treatment. 

 

Do not apply the cuff on an arm with an unhealed wound. 

Summary of Contents for UA-621

Page 1: ...Digital Blood Pressure Monitor Model UA 621 Instruction Manual 1WMPD4001898D...

Page 2: ...ring Data 11 What Is An Irregular Heartbeat 12 Pressure Bar Indicator 12 WHO Classification Indicator 12 About Blood Pressure 13 What Is Blood Pressure 13 What Is Hypertension And How Is It Controlled...

Page 3: ...es X ray or other devices with strong electrical fields Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulat...

Page 4: ...pressure oxygen chamber or an oxygen tent It may cause a fire or explosion Parts Identification Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Battery Indicator I H B...

Page 5: ...ry The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Page 6: ...ory automatically 2 Recalling Data Refer to page 11 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are...

Page 7: ...ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Remo...

Page 8: ...cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 621 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action A...

Page 9: ...ent Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest before taking the mea...

Page 10: ...p inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse...

Page 11: ...tional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure v...

Page 12: ...1 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed 2 The data are automatically displayed...

Page 13: ...Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator...

Page 14: ...uce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can p...

Page 15: ...batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measure...

Page 16: ...Type UA 621 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Number of measurements Approximat...

Page 17: ...33C Input 100 240V Output 6V 500mA TB 233BF Input 240V Output 6V 500mA Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C TB...

Page 18: ...ingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 6...

Reviews: