3-2
Applicable models
■
Functions available for each model, accessories needed for connection to AD-8552EIP.
Accessories needed to connect the
AD8552EIP to a weighing device
EtherNet/IP
Convenient functions
Weighing device
output options
Cable needed for
connection between
weighing device and
AD8552EIP
Data that can be read from the host
Operations that can be made from the host
Power supply
to the
weighing
device
Auto power on
function⋆1
Weighing
value
Status
information
Response
speed
Calibration status
Calibration weight
value
Re-
zero
Zero
Taring
Calibration with
internal weight
Calibration with your
own weight
Changing
the
display
digit
Changing the
response
speed
Changing
the unit
AD-4212C
Unnecessary
Cable included with the
weighing device
○
○
○
○
○
○
×
×
×
○
○
○
×
○
○
AD-
4212D
⋆2
Connector for
A&D’s external
display
Unnecessary
Cable included with the
weighing device
○
○
○
○
○
○
×
×
○
○
○
○
×
○
○
⋆2
Connector for the
PLC
Unnecessary
AX-KO4472-1000
AD-4212A/B
Unnecessary
AX-KO1710-200
○
△※3
×
×
×
○
×
×
×
×
○
×
×
×
○
BA-T
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
○
○
×
×
×
×
×
○
○
BA
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
○
○
○
×
○
×
○
○
○
GX-A、GX-M
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
○
○
○
×
○
×
○
○
○
GF-A、GF-M
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
○
○
×
×
○
×
○
○
○
FZi、HR-AZ
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
×
×
○
×
○
×
○
○
○
FXi、HR-A
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
×
×
×
×
○
×
○
○
○
GX、GX-K、GP
Unnecessary
AX-KO1710-200
○
△※3
×
×
×
○
×
×
○
×
○
×
○
×
○
GF、GF-K
Unnecessary
AX-KO1710-200
○
△※3
×
×
×
○
×
×
×
×
○
×
○
×
○
BM、GH
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
×
×
○
×
○
×
○
×
○
HR-i
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
×
×
×
×
○
×
○
×
○
GR
Unnecessary
AX-KO1710-200
○
△※3
×
×
×
○
×
×
○
×
×
×
○
×
○
FC-i
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
×
×
×
×
×
×
×
×
×
×
HC-i
HC-03i
AX-KO1786-200
○
△※3
×
×
×
×
○
○
×
×
×
×
×
×
×
Eki、Ewi
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
○
×
×
×
×
×
×
○
×
×
EJ、EJ-B
EJ-03
AX-KO2741-180
○
△※3
×
×
×
〇
×
×
×
×
×
×
○
×
×
EK-L
Unnecessary
AX-KO2741-180
○
△※3
×
×
×
〇
×
×
×
×
×
×
○
○
×
HV-CWP
HVW-03CWP
AX-KO3285-320
○
△※3
×
×
×
×
〇
〇
×
×
×
×
○
×
〇
HV-C、HV-CP、
HW-C、HW-CP
HVW-03C
AX-KO2741-180
○
△※3
×
×
×
×
〇
〇
×
×
×
×
○
×
〇
HV-G、HW-G、
HW-WP
Unnecessary
AX-KO1786-200
○
△※3
×
×
×
×
〇
〇
×
×
×
×
○
×
×
FG
FG-23 / FG-24
AX-KO1786-200
○
△※3
×
×
×
×
〇
〇
×
×
×
×
×
×
×
FS-i
FS-03i
AX-KO3285-320
○
△※3
×
×
×
×
〇
〇
×
×
×
×
○
×
×
SC/SE
SCE-03
AX-KO3285-320
○
△※3
×
×
×
〇
×
×
×
×
×
×
×
×
×
SW
SW-03
AX-KO3285-320
○
△※3
×
×
×
×
〇
〇
×
×
×
×
○
×
×
⋆
1
.
If the weighing device does not have an auto power-on function or auto-start function, it is necessary to turn on the display or each weighing device by key operation after turning on the power.
⋆
2
.
The AD4212D has two types of RS-232C connectors. Connect the display connector and the RS-232C connector of AD-8552EIP. (Do not use the PLC connector.)
⋆
3
.
Some functions (calibration error flag) cannot be used.