5. Service, diagnostics and repairs
5.1. Service life
a)
TBO of the module is not defined.
b)
In the case of failure or error, the module must not be used any
more.
5.2. Checks
The following checks are recommended:
1)
At pre-flight check:
a.
Turn on the power to check if operational (the EEM MOT 01
FE…
monitors should display data);
2)
After 100 hours of flight:
a.
Check the instrument
’s electric connections
:
Remove the lid of the monitor casing;
Check if wires sit firmly in screw connection terminal
blocks,
Check for wire damage as frayed insulation;
Place wires flatly and in parallel in the case to avoid
overlapping at the exit from the casing,
Attach the lid.
b.
Turn on the power on to check if operational (check if EEM
MOT 01
FE…
monitors display data);
c.
Read/download EMS DAQ R02.01 records.
5.3. Cleaning and conservation
The casing is to be buffed with water-damped soft cloth. Optionally, if very
dirty, can be cleaned with cloth sparingly damped with mild soap solution.
Caution: avoid spilling liquids over the device.