www.a-ts.cn A-TS Technology RT20
76
Err 27
Absolute encoder
battery alarm
Battery voltage is lower than 3.1V, the battery
voltage is low
Err 28
Absolute encoder
communication
timeout alarm
Feedback from the absolute encoder timed out
Err 29
Torque overload
Motor load exceeds the value and duration set
by user
Err 30
★
Encoder Z pulse lost
Encoder Z pulse lost
Err 31
★
Encoder UVW signal
error
Encoder UVW signal is incorrect or does not
match with the encoder
Err 32
★
Encoder UVW signal
encoding is invalid
The UVW signal is kept at full high or full low
level
Err 33
★
Dynamic memory
allocation error
Dynamic memory allocation error
Err 34
★
Flash reads CRC
error
Flash reads CRC error
Err 35
★
Motor adaptation
error
The motor is not adapted.
Err 36
Watchdog error
Internal watchdog error
Err 37
★
Motor initial zero
lock error
Zero position lock error
Err 38
★
External braking
resistance value is
incorrect
The resistance value of external braking
resistance is less than the minimum allowed
value
Err 51
Multi-turn value
exceeds the set
value
Multi-turn value exceeds the set value
Err 52
Main power supply
under voltage alarm
In the enabled state, the bus voltage is lower
than 245V
Err 53
AC main power
supply failure/ is off
It is powered off in the power supply cable L1,
L2, and L3
Err 54
AC main power
supply phase loss
There is phase loss in power supply cable L1,
L2, and L3
Err 55
★
Dynamic braking
overcurrent
Dynamic braking overcurrent fault