www.a-ts.cn A-TS Technology RT20
48
please check the wiring.
2)
Parameter setting
Set the parameters according to the table below.
Set to AU
mode
Press page
up
01JOG
Long press
Enter key
Press page
up
Press page
down
Motor runs
Motor runs
The motor running speed is set by
PA21. When long press the Enter
key, the servo enable is turned on,
and Long press the Return key, the
servo enable is turned off.
Figure 5-2 JOG trial running block diagram
Parameter
Name
Set value
Factory
value
Parameter
description
PA4
Control mode
5
0
JOG control
PA21
JOG running speed
Appropriate
value
300
JOG speed
PA53
Lower 5 digit input
terminal forced ON
00001
00000
Drive enable
3)
Running
First confirm there is no alarm or any abnormal condition. The motor is
enabled at zero speed.
Select
in the menu level one, and press the Enter key to go
to the JOG trial running mode.
Press the Page up key and hold , the motor runs at JOG speed (PA21)
CW. Release the Page up key, the motor will stop and keep at zero speed.