www.a-ts.cn A-TS Technology RT20
63
7 Parameters
7.1 Parameter list
INSTRUCTIONS
The applicability column shows the applicable control mode. P means position
control applicable, S means speed control applicable, T means torque control
applicable, and ALL means it is applicable for position, speed and torque
control all.
Parameter number plus
★
indicates that after modification the parameter
needs to be saved, to will be effective after the power cycle. Parameter
number without
★
indicates that after modification the parameter will be
effective at once.
Parameter value plus
*
means the factory default may be different, if the
drive model is different.
7.1.1 PA parameters
No.
Name
Parameter
range
Factory
default
Unit
Applica
bility
PA0
Parameter password
0-9999
315
ALL
PA1
★
Motor model
1-132
1
ALL
PA2
★
Drive model
0-4
0
ALL
PA3
★
Initial display status
0-25
0
ALL
PA4
★
Control method
selection
0-16
0
ALL