Pannes s’af
fi
chant sur la commande
Light pulses
Cause
Solution
Remark
3 (SL3)
Three ignition
attempts without
success
No gas supply
1.
Open the mains gas supply valve and/or the manual gas valve
for the gas control.
2.
Check the pre-pressure on the gas control.
3.
If necessary
, restore the gas supply
.
Contact your installation engineer for restoring the gas supply
.
Air in the gas pipe
Bleed the gas pipe.
Contact your installation engineer for replacing the required parts.
No gas supply to
burner
1.
Check if the gas valve switches.
2.
Replace the gas control if necessary
.
Error in the hot
surface igniter circuit
1.
Check if the hot surface igniter has been properly connected.
See
(12.2 “Electrical circuit diagram”)
.
2.
Check the cabling of the hot surface igniter
.
3.
Check the voltage over the hot surface igniter
. This should be
115 V
AC.
4.
Measure the resistance over the hot surface igniter
. This
should be between 45 and 400 Ohms.
5.
Replace the hot surface igniter if necessary
.
Contact the installation engineer in case of reoccurring errors.
Contact the installation engineer for replacing the required parts.
Phase and Zero
incorrectly connected
Correctly connect the Phase and the Zero
(3.9 “Electrical
connection”)
. The device is phase-sensitive.
Error in the ionisation
circuit
1.
Check if the hot surface igniter has been properly connected.
See
(12.2 “Electrical circuit diagram”)
.
2.
Check the cabling of the hot surface igniter
.
3.
Check if the ground wire of the burner has been properly
connected.
4.
Replace the hot surface igniter if necessary
.
Supply voltage too low
Check the supply voltage.
This should be 230V
AC (-15% +10%).
Summary of Contents for TWI 35-130
Page 2: ...www aosmithinternational com your installer...
Page 3: ...Instruction manual TWI 35 130 G TWI 45 190 G 1...
Page 4: ...2 Instruction manual TWI 35 130 G TWI 45 190 G...
Page 6: ...4 Instruction manual TWI 35 130 G TWI 45 190 G...
Page 25: ...Instruction manual TWI 35 130 G TWI 45 190 G 23 Device types IMD 0531 R0...
Page 36: ...34 Instruction manual TWI 35 130 G TWI 45 190 G 4 Conversion to another gas category...
Page 44: ...42 Instruction manual TWI 35 130 G TWI 45 190 G 8 Shut down...
Page 58: ...56 Instruction manual TWI 35 130 G TWI 45 190 G Annex 12...
Page 61: ...Instruction manual TWI 35 130 G TWI 45 190 G 59...
Page 62: ...60 Instruction manual TWI 35 130 G TWI 45 190 G 0308 489 R1 0...