ENG 25
Softener fails
to use salt
•
Water pressure is too low.
•
Brine line plugged.
•
Injector is plugged.
•
Internal control leak.
•
Line pressure must be at least 20 psi.
•
Clean brine line.
•
Clean or replace injector and screen.
•
Check piston, seals and spacers.
Brine container
overflow
•
Call your dealer.
•
Refill time disordered.
Water hardness remains
•
Fail to regenerate automatically.
•
Brine concentration is poor.
•
Injector is plugged.
•
Check power of controller.
•
Keep brine tank full of salt.
•
Disassemble the injector and clear it by washing
with water.
Control backwashes
at excessively
low or high rate
•
Replace with correct size controller.
•
Remove controller and ball. Flush with water.
•
Incorrect backwash controller used.
•
Foreign matter affecting controller operation.
Untreated water leakage
during service
•
Improper regeneration.
•
Leaking of bypass valve.
•
O− ring around riser tube damaged.
•
Incorrect regeneration cycle setting.
•
Repeat regeneration making certain that the correct
salt dosage is set.
•
Replace O− ring.
•
Replace O− ring.
•
Reset regeneration cycle.
PROBLEM
POSSIBLE CAUSE
SOLUTION