ENG 22
• Daily Reserve
This value is used to calculate the reserve capacity.
Reserve Capacity = No. People x DAILY RESERVE.
• BW Overide
This setting can be used to skip the back wash cycle. As an example
if the setting is 10, the system will skip 10 back wash cycles. The setting
will only work if the WATER TYPE is set to CITY for clean water
applications.
Master Options
Press UP + DOWN + MANUAL REGEN. SECONDS / BEEP.
• Forced Regen
When set to ON, the system will start a forced regeneration when
the remaining capacity reaches 3%. The regeneration consists
of 8 minutes of Brine and 12 minutes of Rinse. The 20 minutes
regeneration will restore up to 33% of the system capacity. At the next
regeneration time (2:00 AM), the system will automatically perform
a standard regeneration to restore capacity to 100%.
• Vacation Mode
When set to ON, the system will perform a 10 minute back wash
and 10 minute rinse if there is no water flow detected after 7 days.
The regeneration will occur at the scheduled REGEN TIME.
CAUTION:
The values in this page are for illustration purpose and can be changed by the factory without notice. Please contact Customer Service to confirm proper settings.
VALVE MODE
CHEMFREE-AIR
GREENSAND
SOFTWARE VER.
S1.0A
BRINE DELAY
5.0 SECONDS
SERVICE DELAY
3.0 SECONDS
REFILL DELAY
5.0 SECONDS
METER RATIO
8.00
RINSE DELAY
5.0 SECONDS
BACKWASH DELAY
5.0 SECONDS
PROGRAMMING
COMPLETE
PROGRAMMING
COMPLETE
SOFTWARE VER.
S1.0A
BRINE DELAY
2.0 SECONDS
SERVICE DELAY
5.0 SECONDS
REFILL DELAY
0.0 SECONDS
METER RATIO
8.00
RINSE DELAY
5.0 SECONDS
BACKWASH DELAY
2.0 SECONDS