is
Instruction manual BFC
75
Water leakage
Leakage from a water
connection (threaded)
Tighten the threaded connection
If the leak persists, consult your installation engineer
Condensate leakage
Check that the condensation water discharge is working properly.
Rectify if necessary
Leakage from another
nearby water water
heater or pipe segment
Trace the leak
Leakage from the water
heater tank
Consult the supplier and/or manufacturer
Explosive ignition
Incorrect supply
pressure and/or CO
2
Set (3.11 "Check the supply pressure, gas control valve pressure,
CO
2
value and switching pressure") the correct supply pressure
and/or CO
2
.
If ignition is not improved, consult your installation engineer.
Contaminated burner
Clean the burner (15.4.2 "Cleaning the burner")
Insufficient or no hot
water
The water heater is off Start the water heater (9 "Starting the water heater")
No supply voltage
present
1. Check whether the isolator is ON.
2. Check that there is power to the isolator.
3. Check whether the ON/OFF switch of the controller is ON
(position I).
4. Check whether there is power to the electrical connector block.
5. The measured voltage must be 230 V
AC
(-15%, +10%)
See the electrical diagram (17 "Appendices").
If the error persists, consult your installation engineer.
Hot water supply is
used up
Reduce hot water consumption and give the water heater time to
heat up.
If there continues to be insufficient or no hot water, consult your
installation engineer.
The controller is in the
OFF position.
Switch the controller to the ON position (11.3 "Switching to "ON
mode"").
Temperature (T
set
) is
set too low.
Set temperature (T
set
) to a higher setting (11.4 "Setting the water
temperature").
Indication
Cause
Measure
Remark
Summary of Contents for Cyclone BFC-28
Page 4: ...E2...
Page 6: ...4 Instruction manual BFC gis...
Page 10: ...Contents 8 Instruction manual BFC...
Page 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33...
Page 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is...
Page 58: ...Status of the water heater 56 Instruction manual BFC 8 gis...
Page 62: ...Shutting down 60 Instruction manual BFC 10 gis...
Page 74: ...Service program 72 Instruction manual BFC 12 is...
Page 88: ...Service interval 86 Instruction manual BFC 14 is...
Page 97: ...Instruction manual BFC 95 is...
Page 102: ...Instruction manual BFC 100...