14

HEATER WIRING

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE

MUST BE REPLACED, IT MUST BE REPLACED WITH 105°C WIRE OR ITS

EQUIVALENT, EXCEPT IN THE BURNER HOUSING. IN THIS CASE USE

200°C WIRE.

THE COMPUTER CONTROL REQUIRES A SOURCE OF  STABLE CLEAN

ELECTRICITY FOR PROPER OPERATION. INSTALLING THE HEATER ON

A BRANCH CIRCUIT THAT HAS ELECTRONIC NOISE, IS SUBJECT TO

FLUCTUATIONS IN VOLTAGE LEVEL OR HAS AN APPLIANCE WHICH

GENERATES EMF OF RFI INTERFERENCE CAN CAUSE THE

CONTROLLER TO MALFUNCTION. A HIGH QUALITY POWER

CONDITIONER MUST BE INSTALLED IF THE ABOVE CONDITIONS EXIST.

MALFUNCTIONS CAUSED BY A POOR ELECTRICAL SUPPLY ARE NOT

COVERED UNDER YOUR WARRANTY.

The controller is wired to the heater as shown in figures 16 & 17.  The

model and rating plate provides the electrical information needed to

size the complete heater branch supply.

All electrical work must be installed in accordance with the National

Electrical Code and local requirements.

When installed, the appliance must be electrically grounded in

accordance with local codes or, in the absence of local codes, with

the National Electrical Code, ANSI/NFPA 70.

DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEATER TANK

IS FILLED WITH WATER.

NOTE:  This controller is Polarity Sensitive. If the Hot and Neutral Supply

Voltage is reversed, the controller will not sense flame. Verify polarity

before connecting the unit.

WATER LINE CONNECTIONS

This manual provides detailed installation diagrams (see back section of

this manual) for typical methods of application for the water heaters.

The water heater may be installed by itself, or with a separate storage

tank. When used with a separate storage tank, the circulation may be

either by gravity or by means of circulating pump. When a circulating pump

is used, it is important to note that the flow rate should be slow so that there

will be a minimum of turbulence inside the heater.

CLOSED SYSTEM

 CAUTION

A closed system will exist if a check valve (without bypass), pressure

reducing valve (without bypass), or a water meter (without bypass) is

installed in the cold water line between the water heater and street main

(or well).

Excessive pressure may develop causing premature tank failure or

intermittent relief valve operation. This type of failure is not covered by the

limited warranty. An expansion tank or a similar device may be required in

the inlet supply line between the appliance and the meter or valve to

compensate for the thermal expansion of water under supply pressure.

If a water heater is installed in a closed water system, check local codes

or contact the water supplier or local plumbing inspector on how to control

this situation.

FIGURE 16

BSR BOARD (BTH - 250 ONLY)

Summary of Contents for BTH 120 - 250

Page 1: ...any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier cal...

Page 2: ...20 125 000 Nat 60 475 356 285 237 203 178 158 142 129 119 110 102 BTH 120 120 000 L P 60 456 342 274 228 195 171 152 137 124 114 105 98 BTH 150 150 000 Nat 100 570 427 342 285 244 214 190 171 155 142...

Page 3: ...hecking the proper functioning of the heater In addition to these instructions the equipment shall be installed in accordance with those installation regulations in force in the local area where the i...

Page 4: ...r may be able to make minor operational adjustments and save himself unnecessary service calls However the user should not attempt repairs which are not listed in this section WATERTEMPERATURECONTROL...

Page 5: ...personal injury or death Do not apply insulation to the top or the upper 15 of the water heater as this will interfere with safe operation Do not cover the temperature pressure relief valve Do not cov...

Page 6: ...TEDTOTHEOUTDOORS AND HAS ADEQUATE AIR SUPPLY TO AVOID RISKS OF IMPROPER OPERATION FIRE EXPLOSIONORASPHYXIATION VENT PIPE TERMINATION NOTE Before installing venting determine place of vent pipe termina...

Page 7: ...E ON AIR INTAKE TERMINAL DIRECT VENT HORIZONTAL VENT FIGURE 6 DO NOT TERMINATE EXHAUST OVER PUBLIC AREA WHERE CONDENSATE OR VAPOR CAN CAUSE NUISANCE OR HAZARD EXHAUST VENT HOOD MUST BE LOCATED 1 MINIM...

Page 8: ...n the vent system layout so that proper clearances are maintained from plumbing and wiring Vent pipes serving power vented appliances are classified by building codes as vent connectors Required clear...

Page 9: ...the holes by drilling a hole through the center of the template from the inside through to the outside The template can now be positioned on the outside wall using the drilled holes as a centering po...

Page 10: ...ith a plumbing roof boot or equivalent flashing 3 The intake vent termination and the exhaust vent termination must penetrate the same side of roof 4 The center line of the intake vent termination and...

Page 11: ...intake and six 6 on the exhaust A 90 elbow is equal to five 5 equivalent feet of pipe One 1 90 elbow is equal to two 2 45 elbows Any venting configuration using less than 50 equivalent feet should use...

Page 12: ...improvements have been made to strengthen the igniter it is still fragile and care must be taken when handling the igniter to prevent breakage GAS PIPING Contact your local gas service company to ensu...

Page 13: ...rements of all other gas fired equipment supplied by the meter If the gas meter is too small ask the gas company to install a larger meter having adequate capacity GAS PRESSURE REGULATION Main line ga...

Page 14: ...Sensitive If the Hot and Neutral Supply Voltage is reversed the controller will not sense flame Verify polarity before connecting the unit WATER LINE CONNECTIONS This manual provides detailed install...

Page 15: ...the state of other system devices If the temperature drops below the setpoint value less differential the control will automatically return to step 2 and repeat the entire operating cycle During this...

Page 16: ...ate 3 Not Implimented h s 240 Executed State 4 Not Implimented h s 210 Executed State 10 Not Implimented h s 213 Executed State 13 Not Implimented h s 214 Executed State 14 Not Implimented h s 216 Exe...

Page 17: ...ol problem 2 Water in tank above freezing 2 Temperature probe out of tolerance replace temp probe PossibleCause Remedy 1 Water in tank is low probe 1 Fill tank immersed in steam 2 Probe wiring shorted...

Page 18: ...unit is equipped with the correct orifice PRIOR TO START UP REQUIREDABILITY INSTALLATIONORSERVICEOFTHISWATERHEATERREQUIRESABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED PLUM...

Page 19: ...19 FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life...

Page 20: ...below 160 F HIGH ALTITUDE INSTALLATIONS WARNING BTH HEATERS ARE CERTIFIED FOR USE WITHOUT MODIFICATION FOR ALTITUDES UP TO 6500 FEET INSTALLATIONS ABOVE 6500 FEET MAY REQUIREREPLACEMENTOFTHEBURNERORIF...

Page 21: ...drain valve when finished flushing 4 Turn on the heater electrical disconnect switch DRAINING The heater must be drained if it is to be shut down and exposed to freezing temperatures Maintenance and s...

Page 22: ...operation and a tank explosion In areas with poor water conditions it may be necessary to inspect the T P valve more often than every three years CAUTION BEFOREMANUALLYOPERATINGTHEVALVE MAKESURETHATA...

Page 23: ...WATER SUPPLIED TO FIXTURES PIPE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH LOCAL CODES CAUTION IF BUILDING COLD WATER SUPPLY HAS A BACK FLOW PREVENTER CHECK VALVEORWATERMETERWITH CHECK VALVE PROVISIONS...

Page 24: ...GER TEMPERATURE SETTING SHOULD NOT EXCEED SAFE TEMPERATURE AT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 4 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT AD...

Page 25: ...NIFOLD KIT SPECIFICATIONS PAGE28 CAUTION IF BUILDING COLD WATER SUPPLY HAS A BACK FLOW PREVENTER CHECK VALVE OR WATER METER WITH CHECK VALVE PROVISIONSFORTHERMALEXPANSIONOFWATERINTHEHOTWATER SYSTEM MU...

Page 26: ...RCULATINGLINEOF180 FORBOOSTEDWATER IF USED TOINLETWATERLINETOBOOSTER INSTALLINACCORDANCEWITHLOCALCODES TWO TEMPERATURE TWO HEATERS ONE PRE HEATER ONE BOOSTER HEATER WITH OR WITHOUT BUILDING RECIRCULAT...

Page 27: ...INTHETANK NOTE4 IFTEMPEREDWATERISRECIRCULATED RETURNLINESHOULD BECONNECTEDATPOINTA DANGER TEMPERATURESETTINGSHOULDNOTEXCEEDSAFETEMPERATUREAT FIXTURES SEEWATERTEMPERATURECONTROLWARNINGONPAGE5 IF HIGHER...

Page 28: ...er heating and storage potential of the system cannot be achieved Plus the units with the higher water flow may have a shortened life Unions shown in piping diagrams are not included in the manifold k...

Page 29: ...leaned Refer to MAINTENANCE for details 2 Some of the electrical components of the water heater make sounds which are normal Contacts click or snap as the heater starts and stops Transformers often hu...

Page 30: ...0 W C or lower than the minimal gas supply pressure as shown in Table 4 that is for Natural Gas 5 0 W C for BTH 120 250 or 4 5 W C for BTH 150 199 or for L P Gas 11 0 W C pressure Also the manifold p...

Page 31: ...r the limited warranty the warrantor will provide only a replacement water heater or part thereof The owner is responsible for all other costs Such costs may include but are not limited to a Labor cha...

Page 32: ...32 A O SMITH WATER PRODUCTS CO INC 5621 W 115TH STREET ALSIP ILLINOIS 60803 PHONE 1 800 433 2545 FAX 1 800 433 2515 WWW HOTWATER COM E MAIL PARTS HOTWATER COM...

Reviews: