3.6
Status of the water heater
During operation, the display shows the status of the water heater.
3.6.1
Operating modes
When running, the water heater has four basic operating modes, namely:
OFF (see section 3.6.1.1)
ON (see section 3.6.1.2)
EXTRA (see section 3.6.1.3)
PROG (see section 3.6.1.4)
3.6.1.1
OFF
In this mode, the frost protection is activated. The figure shows the display with the
following information:
line one: the text OFF;
line two: the time, the day and T
(see section 4.1.1).
lines three and four: the text FROST PROTECTION ACTIVATED.
3.6.1.2
ON
In this mode, the water heater continually responds to the hot water demand. The figure
shows the display with the following information:
line one: the text ON;
line two: the time, the day and T
(see section 4.1.1).
line three: the programmed water temperature T
set
;
line four: is empty when the water heater is idle, or depending on the operating cycle
(see section 4.1.1), displays a text such as HEAT DEMAND.
3.6.1.3
EXTRA
In this mode, one extra period is programmed and activated. In this mode, the OFF or
PROG mode is temporarily overruled to fulfill a single period of demand. When the period
has passed, the water heater automatically returns to the previous operating mode. The
figure shows the display with the following information:
line one: the text EXTRA;
line two: the time, the day and T
(see section 4.1.1);
line three: the switch-on time and the related water temperature setting;
line four: the text PERIOD ACTIVATED.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0311704_BFC_28-120_III_
ENEN_V2.4, 2022-10-17
21
Summary of Contents for BFC Cyclone
Page 6: ...6...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41...
Page 42: ...42 User part...
Page 46: ...46 Installation Maintenance and Service part...
Page 52: ...52 Installation Maintenance and Service part...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59...
Page 76: ...76 Installation Maintenance and Service part...
Page 78: ...78 Installation Maintenance and Service part...
Page 84: ...84 Installation Maintenance and Service part...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part...