6.3
Safety devices
6.3.1
Protection for the water heater
6.3.1.1
Water temperature protection
Using temperature sensors T
1
(7) and T
2
(13), the controller monitors three temperatures
that are important for safety. The table explains the functioning of the temperature
sensors.
Safety
Description
Anti-frost
(T
1
< 5 ºC or T
2
< 5 ºC)
The frost protection cuts in. The water is heated to
20 °C.
Maximum water
temperature:
(T
1
> 88 ºC or T
2
>
88 ºC)
The high-limit safeguard serves to prevent
overheating and/or excessive formation of scale in
the appliance. If the high-limit safeguard is
activated, heating is stopped. This causes the
water in the tank to cool down. Once the water has
cooled sufficiently (T
1
< 81°C), the controller
resets the appliance.
For extra safety
(T
1
> 93 ºC or T
2
>
93 ºC)
A lockout error of the water heater controller takes
place. (see section 11) The controller must be
manually reset before the appliance can resume
operation. The reset may only be performed if T
1
<
81°C.
6.3.1.2
Gas control valve
The controller opens the gas control valve so that gas can be supplied to the burner. As a
safety measure, the gas control valve has two valves. Both valves shut off the gas supply.
6.3.1.3
Fan
The fan (18) provides an optimum air supply when there is a heat demand. As a safety
feature, the fan ensures that any gases present in the combustion chamber are removed,
both before and after combustion. We refer to this as pre- and post-purge.
The fan speed is continuously monitored by the controller (4). The controller takes control
if the fan rpm varies too much from the value set.
6.3.1.4
Pressure switch
The pressure switch only guarantees the supply of air during pre-purging of the water
heater. If the pressure difference during pre-purging is sufficient, the pressure switch
closes. Refer to the general and electric specifications in the appendices (see section 12)
for the trip point for each water heater.
Note
The trip point of the pressure switch is not adjustable.
6.3.1.5
Flame probe
To ensure that no gas can flow when there is no combustion, the water heater is fitted
with a flame probe (21). The controller uses this probe to detect the presence of a flame,
by means of ionisation detection. The controller closes the gas control valve the instant it
detects that there is a gas flow but no flame.
n
0311704_BFC_28-120_III_
ENEN_V2.4, 2022-10-17
49
Summary of Contents for BFC Cyclone
Page 6: ...6...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41...
Page 42: ...42 User part...
Page 46: ...46 Installation Maintenance and Service part...
Page 52: ...52 Installation Maintenance and Service part...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59...
Page 76: ...76 Installation Maintenance and Service part...
Page 78: ...78 Installation Maintenance and Service part...
Page 84: ...84 Installation Maintenance and Service part...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part...