Cable colors:
Components:
Terminal block connections:
1
Brown
A
Control
J2
Power connection for controller
2
Blue
B
Flame probe
J19
Extra error signal connection
3
Yelow/Green
C
Hot surface igniter
J20
Gas control valve connection
4
Black
D
Gas control valve
J21
Program-controlled pump
connection
5
White
E
Burner earth connection
6
Grey/Beige
F
External ON mode switch
J40
Fan connection
7
Green
G
Program-controlled pump
(max. 100 W)
J36
Controller display connection
JP2
Flame probe and hot surface
igniter connection
Terminal block connections:
H
Extra error signal connection
A
Earth
J
Isolating transformer
JP3
Temperature sensor
T
2
connection
N
Neutral
K
Double-pole isolator
L
Live input of controller
L
Controller O/I switch
JP4
Dummy connection
L
1
Phase input of isolating
transformer (primary side)
M
Display
JP5
Temperature sensor
T
1
connection
N
Fan
L
2
Phase input of isolating
transformer (secondary side)
O
Temperature sensor
(T
2
- bottom of tank)
JP6
Selection resistor and pressure
switch connection
L
3
Phase input of
program-controlled pump
P
Dummy
JP8
Extra ON mode switch connection
Q
Temperature sensor
(T
1
- top of tank)
R
Selection resistor
F1
Fuse (T 3.15 A - 250 V)
S
Push button
F3
Fuse (T 3.15 A - 250 V)
T
Electrical anodes
U
Signaling for electrical anodes
V
Potentiostat
110
Installation, Maintenance and Service part
Summary of Contents for BFC Cyclone
Page 6: ...6...
Page 13: ...User part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 41: ...Installation Maintenance and Service part 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 41...
Page 42: ...42 User part...
Page 46: ...46 Installation Maintenance and Service part...
Page 52: ...52 Installation Maintenance and Service part...
Page 59: ...Fig Venting systems 0311704_BFC_28 120_III_ENEN_V2 4 2022 10 17 59...
Page 76: ...76 Installation Maintenance and Service part...
Page 78: ...78 Installation Maintenance and Service part...
Page 84: ...84 Installation Maintenance and Service part...
Page 102: ...Fig Dimensions BFC 28 30 50 60 102 Installation Maintenance and Service part...
Page 104: ...Fig Dimensions BFC 80 100 120 104 Installation Maintenance and Service part...
Page 112: ...12 7 Declaration of conformity 112 Installation Maintenance and Service part...
Page 113: ......
Page 114: ......
Page 118: ...116 Installation Maintenance and Service part...