A.O. Smith AOW-3000 Owner'S Manual Download Page 9

NEED HELP? GIVE US A CALL

 833.232.9711

NEED HELP? GIVE US A CALL

 833.232.9711

CARE AND MAINTENANCE

12

AOW-3000

Replacement cartridge AO-4000-CARBON  

and AO-RO-RM-R

Membrane Production

1  

35 gpd (132 lpd)

Membrane TDS Reduction

1  

95% minimum

System Production

2  

13.32 gpd (50.4 lpd)

TDS Reduction

2    

96.3%+ average

Max TDS  1000 ppm

Max water hardness @ 6.9pH  10 gpg (2.64 gpL)

Max Chlorine in water  3.0 ppm

Supply water pH limits  4-10

Drain (reject water) Flow  3-5x product flow

Empty Storage Tank Precharge 5-7 psi air (35-48 kPa)

Storage Tank Capacity

2  

3.2 gallons (12.11 liters)

Supply water pressure limits  40-100 psi (275-689 kPa)

Supply water temperature limits  40-100° F (5-37° C)

Efficiency

3

   17.91%

Recovery

4  

29.43%

13

Specifications – Qualified System 
Performance
Because the performance of a Reverse  
Osmosis Membrane is highly dependent 
upon pressure, temperature and Total  
Dissolved Solids (TDS), the following should 
be used for comparison purposes only.

Industry standards measure RO Membranes 
performance with no back pressure on the 
product water, at 60 psig (414 kPa) and 77°F 
(25°C). Further conditions on the above are 
250 ppm TDS and a 30.6% recovery rate.  
Production rate and TDS reduction figures 
are for a new Membrane that has been 
rinsed for 24 hours. The production rate of 
a new Membrane can decrease by 10% per 
year or more, depending upon the scaling 
and fouling tendencies of the Feed Water.

Measured at 50 psi, 77°±2°F, and 717 mg/l 
TDS per NSF/ANSI Standard 58.

Efficiency rating is the percentage of the 
influent water to the System that is available 
to the user as reverse osmosis treated water. 
This measurement is taken under operating 
conditions that approximate typical  
daily usage.

Recovery rating is the percentage of the 
influent water to the membrane portion  
of the System that is available to the user 
as reverse osmosis treated water when the 
System is operated without a storage Tank  
or when the storage Tank is bypassed.

Nitrate/Nitrite Test Kit:

This System is acceptable for treatment  
of influent concentration of no more  
than 27 mg/L nitrate and 3 mg/L nitrite in  
combination measured as N.* This System  
is supplied with a nitrate/nitrite test kit.  
Product water should be monitored 
periodically according to the instructions 
provided with the test kit.

Drain Flow Restrictor

The restrictor is vital for proper operation of 
RO Membrane Cartridge as it keeps water 
flowing through the membrane at the 
proper rate ensuring the water produced 
is the best quality. It is recommended the 
restrictor assembly be periodically inspected 
to be sure it is clean and unrestricted. 
If service is required on the drain flow 
assembly, disassemble and reassemble as 
outlined in Step 5.

Flow rate and output are determined  
by 3 factors:

1

  Incoming water temperature

 Total dissolved solids (TDS) present in 

supply water

 Incoming water pressure

Lower temperatures are directly propor-
tional to slower flow rate. All membranes 
are tested at 77°F. Incoming water tem-
perature should not exceed 100°F. The RO 
Filter System should also not be installed 
in a location susceptible to freezing. The 
more TDS in the supply water, the more 
filter time is required. Incoming TDS should 
not exceed 1000 ppm. Higher water pres-
sure enables a higher flow rate. Pressure 
must be above 40 psi for proper system 
operation. You may consider installing a 
permeate pump or booster pump if your 
pressure is below 40 psi.

Carbon Pre-Filter &  
Claryum

®

 Post-Filter  

- Change every 6 months* 

The Carbon and Claryum

®

 filter cartridges 

are replaceable activated carbon 
cartridges located in Stages 1 and 3. It is 
recommended replacing these cartridges 
at least every 6 months. You may need to 
replace more often with high water usage 
or high sediment level. Timely replacement 
of these cartridges will protect the RO 
Membrane from high levels of chlorine 
and/or sediment. As these filters build up 
with sediment, you may notice slower 
water output.

RO Membrane Cartridge  
- Change every 12 months

The RO Membrane is located in Stage 
2. This membrane reduces the dissolved 
solids and organic matter. Most municipally 
treated water has a 7.0-7.5 pH, in this 
case you would need to replace your RO 
Membrane every 12 months. Membrane 
life depends on pH and supply water 
hardness. Higher pH shortens membrane 
life by causing pin-hole leaks. When 
output, water quality and production rate 
decrease, it is time to replace the filter.

Remineralizer  
- Change every 12 months*

The Remineralizer is Stage 4. It is  
designed to provide healthy amounts  
of calcium, magnesium and potassium  
for great-tasting water.  

*Filter life depends on water usage and 
water supply quality.

CAPACITY AT VARIOUS WATER PRESSURE LEVELS (WITH 5 PSI PRECHARGE) U.S. GALLONS

TOTAL VOLUME

20 PSI

30 PSI

40 PSI

50 PSI

60 PSI

70 PSI

3.2

1.4

1.8

2.0

2.2

2.4

2.5

NON-POTABLE WATER SOURCES: 

Do not attempt to use this product to make safe drinking water from non-potable water sources. 

Do not use the System on microbiologically unsafe water, or water of unknown quality without adequate disinfection before or after the 

System. This System is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts.

INSTALLATIONS IN THE COMMONWEALTH OF MASSACHUSETTS: 

The Commonwealth of Massachusetts requires installation be 

performed by a licensed plumber and does not permit the use of saddle valves. Plumbing code 248—CMR of the Commonwealth of 

Massachusetts must be followed in these cases.

Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the System.  

Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Filter is only to be used with cold water. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

Summary of Contents for AOW-3000

Page 1: ...NER S MANUAL Use this owner s manual to reference installation troubleshooting and filter replacement information If you need help or have a question we ve got you covered Give us a call at 833 232 97...

Page 2: ...AOW 3000 REVERSE OSMOSIS With Claryum Osmosis inversa con Claryum Owner s Manual El manual del proprietario...

Page 3: ...Q CARBON FILTER CARTRIDGE R CLARYUM FILTER CARTRIDGE BLUE S SCREWS BRACKET T BRASS TEE B C D Note We recommend using an approved or certified professional if drilling is required Basic plumbing knowl...

Page 4: ...e a seal Do not connect the other end at this time Note Use a wrench to ensure complete seal Avoid over tightening Note If you have metal drain pipes consult a plumber for installation of drain connec...

Page 5: ...ackets using 1 8 drill bit for the System Manifold Note Do not drill into anything beyond the cabinet wall 4 Insert anchors and mounting screws into the wall leaving approximately 3 8 of each screw ex...

Page 6: ...KET NEW HOLE 3 Knock center hole out align holes and attach to front plate of drain connector L INSTALLATION GUIDE 6 7 WARNING Ensure that all electrical appliances and outlets are turned off at the c...

Page 7: ...the Manifold port labeled Tank Push the tubing all the way in until it stops STEP 6 Connect tubing 5 Faucet to Drain Connector 3 8 red tubing from faucet Take the 3 8 red tubing from faucet and insert...

Page 8: ...ater See purge instructions below Note Sanitization is recommended immediately after RO Filter System installation and any inner part servicing The person sanitizing must have clean hands during this...

Page 9: ...r 3 Incoming water pressure Lower temperatures are directly propor tional to slower flow rate All membranes are tested at 77 F Incoming water tem perature should not exceed 100 F The RO Filter System...

Page 10: ...boratory conditions actual performance may vary Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts See owner s manual for general installation con...

Page 11: ...11 or watertreatmentpro aosmith com within the Warranty Period and describe the problem to a customer service representative who will verify that the product is under warranty and arrange for delivery...

Page 12: ...ar el tubo blanco de 3 8 de la llave que viene instalado previamente para conectar al tanque y luego al colector Mida el tubo desde el orificio de la llave hasta la salida del colector del sistema Ase...

Page 13: ...te el tubo blanco de 1 4 a la T de lat n de la siguiente forma Deslice la tuerca de compresi n en el tubo blanco con las roscas de la tuerca orientadas hacia el extremo del tubo Luego deslice el mangu...

Page 14: ...ANDELA TUERCA DE LA LLAVE 1 Aplique 4 o 5 vueltas hacia la derecha de cinta de Tefl n alrededor del niple en la parte superior del tanque en la misma direcci n que las roscas 2 Apriete el conector del...

Page 15: ...macorrientes est n apagados desde el disyuntor antes de realizar trabajos en el rea del gabinete PRECAUCI N Use gafas de seguridad para proteger sus ojos mientras perfora 6 Apriete firmemente las tuer...

Page 16: ...por completo hasta que se detenga PASO 6 Conexi n de los tubos 5 Llave al conector de drenaje tubo rojo de 3 8 desde la llave Tome el tubo rojo de 3 8 desde la llave e ins rtelo completamente en el c...

Page 17: ...o de OI y despu s del mantenimiento de cualquier pieza interna La persona que desinfecte debe tener las manos limpias durante este proceso IMPORTANTE Complete la desinfecci n antes de la prueba de pre...

Page 18: ...de osmosis inversa sin contrapresi n en el agua de producto a 414 kPa 60 psig y 25 C 77 F M s condiciones acerca de lo anterior son TDS de 250 ppm y una velocidad de recuperaci n de 30 6 Las cifras de...

Page 19: ...eptable para el tratamiento de una concentraci n entrante no mayor que 27 mg L de nitrato y 3 mg L de nitrito en combinaci n medidos como N Este sistema incluye un kit de prueba de nitrato y nitrito S...

Page 20: ...en el sitio web de la Agencia de Protecci n Ambiental de EE UU epa gov safewater arsenic Hay dos formas de ars nico ars nico pentavalente As V As 5 y arseniato y ars nico trivalente tambi n llamado As...

Page 21: ...n Resultados Perfluorooctanoic acid PFOA Perfluorooctane sulfonate PFOS 1 5 10 ug L 0 07 ug L 96 Aprobado Solo para uso con agua tratada localmente No usar con agua que no sea microbiol gicamente seg...

Page 22: ...mage or failure Use of parts from other manufacturers will also void your warranty Please visit AOSmithAtLowes com for replacement parts Installation must comply with state and local ordinances A O Sm...

Reviews: