F11 (blocking error)
Flame detection with
closed gas valve.
Defective gas valves
See F07.
F12 (lock out error)
The flue gas backflow
safeguard is activated.
Chimney flue blocked
1. Check for blockages in the chimney flue pipe
2. Remove any blockages
3. Reset electronic controller.
If the error cannot be resolved or is persistent, contact your
installation engineer
F13 (lock out error)
Flue damper not driven
by the motor
The motor fails to open
the flue damper
See
F10
If the error cannot be resolved or is persistent, contact your
installation engineer
F14 (lock out error)
The microswitch fails to
monitor the position of
the flue damper
The microswitch fails to
detect the position of
the flue damper
1. Check that the red arrow on the motor goes fully to the right
and/or left
2. Check that the microswitch is activated when the damper
rotates
If the error cannot be resolved or is persistent, contact your
installation engineer
Symptom
Cause
Solution
Remark
Summary of Contents for ADMR-115
Page 4: ...4 Instruction manual ADMR gis...
Page 8: ...Table of contents 8 Instruction manual ADMR...
Page 12: ...Introduction 12 Instruction manual ADMR 1 gis...
Page 38: ...Installation 38 Instruction manual ADMR 3 is...
Page 56: ...Shutting down 56 Instruction manual ADMR 10 gis...
Page 64: ...Main menu 64 Instruction manual ADMR 11 gis...
Page 78: ...is Instruction manual ADMR 78...
Page 80: ...Maintenance frequency 80 Instruction manual ADMR 14 is...
Page 86: ...Performing maintenance 86 Instruction manual ADMR 15 s...
Page 94: ...Appendices 94 Instruction manual ADMR 17 is...
Page 96: ...Instruction manual ADMR 96...