OPERATIONAL AND ADJUSTMENT PROCEDURE (INITIAL START UP)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. THIS APPLIANCE DOES NOT HAVE A PILOT. IT IS
EQUIPPED WITH AN IGNITION DEVICE WHICH
AUTOMATICALLY LIGHTS THE BURNER. DO NOT TRY
TO LIGHT BURNER BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE
APPLIANCE AREA FOR GAS. BE SURE TO SMELL
NEXT TO THE FLOOR BECAUSE SOME GAS IS
HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR.
WHAT TO DO IF YOU SMELL GAS:
•
DO NOT TRY TO LIGHT ANY APPLIANCE.
•
DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE
ANY PHONE IN YOUR BUILDING.
•
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A
NEIGHBOR’S PHONE. FOLLOW THE GAS SUPPLIER’S
INSTRUCTIONS.
•
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL
THE FIRE DEPARTMENT.
C. USE ONLY YOUR HAND TO PUSH IN OR TURN THE
GAS CONTROL KNOB. NEVER USE TOOLS. IF THE
KNOB WILL NOT PUSH IN OR TURN BY HAND, DON’T
TRY TO REPAIR IT. CALL A QUALIFIED SERVICE
TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY
RESULT IN A FIRE OR EXPLOSION.
D. DO NOT USE THIS APPLIANCE IF ANY PART HAS
BEEN UNDER WATER. IMMEDIATELY CALL A
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE
APPLIANCE AND TO REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL WHICH
HAS BEEN UNDER WATER.
E. DO NOT OPERATE APPLIANCE UNLESS UNIT IS
FILLED WITH WATER AND INLET LINES ARE FULLY
OPEN.
OPERATING INSTRUCTIONS
1.
STOP! READ THE SAFETY INFORMATION
ABOVE ON THIS LABEL.
2. REMOVE APPLIANCE THERMOSTAT COVER. ROTATE
THE THERMOSTAT DIAL COUNTERCLOCKWISE
TO LOWEST SETTING.
3. TURN OFF ALL ELECTRIC POWER TO THE
APPLIANCE.
4. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY LIGHTS THE
BURNER. DO NOT TRY TO LIGHT THE BURNER BY
HAND.
5. TURN GAS VALVE CONTROL KNOB CLOCKWISE
T O “OFF” (FIG.A). NOTE: HALFWAY THRU THE TURN,
THE KNOB WILL POP UP. CONTINUE TO TURN UNTIL
KNOB LOCKS INTO THE “OFF” POSITION.
6. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF
YOU THEN SMELL GAS:
STOP! FOLLOW “B” IN THE SAFETY
INFORMATION ABOVE IN THIS LABEL. IF
YOU DON’T SMELL GAS, GO TO NEXT
STEP.
7. TURN GAS VALVE CONTROL KNOB
COUNTERCLOCK WISE TO “ON” (FIG. B). NOTE
HALFWAY THRU THE TURN DEPRESS THE KNOB
AND CONTINUE TURNING UNTIL IT LOCKS INTO THE
“ON” POSITION.
8. TURN ON ALL ELECTRIC POWER TO THE
APPLIANCE.
9. SET THERMOSTAT TO DESIRED SETTING. HEATER
WILL AUTOMATICALLY BEGIN OPERATION. MOTOR
WILL RUN APPROXIMATELY 45 SECONDS
(PREPURGE), THEN MAIN BURNER IGNITION WILL
OCCUR.
10.REPLACE THERMOSTAT CONTROL COVER.
11. HEATER IS EQUIPPED WITH AN IGNITION MODULE
WHICH LOCKS OUT AFTER AN UNSUCCESSFUL
IGNITION ATTEMPT. IF MAIN BURNER DOES NOT
LIGHT DURING THIS PERIOD, REPEAT STEPS 2
THRU 9. IF THE APPLIANCE WILL NOT OPERATE,
FOLLOW THE INSTRUCTIONS, “TO TURN OFF GAS
TO APPLIANCE”, AND CALL YOUR SERVICE
TECHNICIAN OR GAS SUPPLIER.
1. REMOVE THERMOSTAT CONTROL COVER.
2. SET THE THERMOSTAT TO LOWEST SETTING.
3. TURN OFF ALL ELECTRIC POWER TO THE APPLIANCE IF SERVICE IS TO BE PERFORMED.
4. TURN GAS VALVE CONTROL KNOB CLOCKWISE
TO “OFF”. REFER TO STEP 5 OF “OPERATING
INSTRUCTIONS” ABOVE.
5. REPLACE THERMOSTAT CONTROL COVER.
TO TURN OFF GAS TO APPLIANCE