![background image](http://html1.mh-extra.com/html/a-o-smith/100-series/100-series_installation-and-operating-manual_3130143007.webp)
7
MODEL CHARACTERISTICS
MODEL CHARACTERISTICS
Table 1. Gas Pressure and Electrical Characteristics
*Manifold Pressure
Minimum
Supply Pressure
Maximum
Supply Pressure
Electrical Characteristics
Gas Type
In. W.C. (kPA)
In. W.C.(kPA)
In W.C.(kPA)
Volts/Hz
Amperes
Natural
0” (0)
3.5(1.10)
14(3.49)
120/60
<10
* The manifold pressure is the factory setting and is not adjustable. A negative pressure will be seen with just the blower
running without the Gas Control Valve open.