background image

UF-216 WATER FILTRATION SYSTEM

16

P/N 1010885 07/04

UF-216 WATER FILTRATION SYSTEM

17

P/N 1010885 07/04

MAINTENANCE

The filtration system is designed to require very little 

maintenance.  To ensure that the water is of the highest 

quality, occasionally some service is required.

Manual Flushing

NOTE: Manual flushing only works when the unit is 

in Flush Interval mode (Fi).  

While the unit is in Flush Interval mode (decimal point 

flashing), hold the Start button down for 6-7 seconds 

until the LED displays 

FL

 (Figure 14).  

Continue holding the button down to keep the drain 

open.  The drain will remain open for as long as the 

Start button is pressed (

FL

 will flash on the LED dis-

play).  
Releasing the Start Button closes the drain and puts 

the unit back into start up mode.  After ten seconds, if 

the Start Button is not pressed the unit automatically 

returns to Flush Interval mode (

Fi

).

Checking the Timer Program

During normal operation, the system displays the time 

setting for the Flush Interval Mode (

Fi

) and the decimal 

will flash in one second intervals.  

NOTE: This is the time between flushing, not a time-

of-day setting.  

Over time, it is possible that the system flush will occurs 

at a time of high water use.  If this creates a problem, 

the timer can be reset by unplugging the power cord, 

waiting for 5 seconds, and plugging the power cord 

in again.  The timer then begins timing from the point 

power is restored to the system.  Follow the procedures 

within the Operation section of this manual to check 

and set the timer settings.

Changing the Cartridges

The UF-216 system uses two types of filtration: Carbon 

Block filtration and capillary membrane filtration.  While 

the filtration system is designed for long life, eventually 

the cartridges will need to be replaced.

CHANGING THE CARBON FILTER CARTRIDGE

To change the Carbon Filter Cartridge, follow the steps 

under 

Install and Flush the Carbon Filter Cartridge

 

in the Installation section of this manual.

CHANGING THE CAPILLARY MEMBRANE FILTER 

CARTRIDGE

   1.  Open the faucet or tap closest downstream to the 

filtration system and close the inlet water valve 

and allow the system to depressurize.

   2.  Place a bucket under the strainer at the inlet 

connection to the system.  Open the strainer by 

unscrewing the cap.  Water will flow out of the 

strainer as the system drains.

   3.  Press and hold the Start button to help drain the 

system.

   4.  Reattach the cap on the strainer when the water 

flow stops.  Unplug the power cord.

   5.  Using a strap wrench (up to 6” capacity), loosen 

the top and bottom end caps. 

DO NOT 

remove 

the top and bottom End Caps yet.

   6.  Disconnect the permeate port connection.

   7.  Using a screwdriver, remove the screws from the 

cartridge bracket and set the bracket and screws 

aside.

   8.  Unscrew the cartridge end caps from the car-

tridge, being careful to retain the O-rings from 

each cap.  Set the O-rings aside.

   9.  Install a new cartridge to the system using the 

cartridge bracket and screws saved from Step 8.

 10.  Connect the permeate port connection.

  11.  Inspect the O-rings to make sure they are clean 

and are not splitting or cut.  For all O-rings, make 

sure they are lubricated with an approved food 

grade lubricant acceptable for drinking water use.

 12.  Screw the cap onto the cartridge.  Tighten with 

strap wrench as necessary.

 13.  Follow the Flushing and Starting the System and 

Sanitizing the System and Lines procedures in the 

Installation section of this manual to complete the 

cartridge change.

SYSTEM SANITIZATION

Over time and use, the plumbing downstream from the 

system may require sanitization.  It is recommended 

that the system and downstream plumbing be sani-

tized at least once a year.  When necessary, follow the 

Sanitizing the System and Lines

 procedure in the 

Installation section of this manual.

Summary of Contents for UF-216C Series

Page 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...

Page 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and ar...

Page 3: ...afety the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this...

Page 4: ...TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a prope...

Page 5: ...ualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cart...

Page 6: ...UF 216 WATER FILTRATION SYSTEM 6 P N 1010885 07 04 SPECIFICATIONS continued Figure 2a Components Components Inlet Nipple Permeate Nipple Drain Nipple Power Cord Shroud...

Page 7: ...UF 216 WATER FILTRATION SYSTEM 7 P N 1010885 07 04 LED Display Program Button Power Cord Filter Cartridge Strainer Permeate Drain Inlet Figure 2b Components SPECIFICATIONS continued Components...

Page 8: ...r to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or Teflon tape on pipe threads Be careful not to get the pipe sealant inside the pipe when making t...

Page 9: ...line Check with local codes for the proper specification DRAIN LINE PLUMBING The drain line is used to flush away the particle buildup when cleaning the filter The drain line must be able to support...

Page 10: ...nd FL will appear on the display 5 Continue holding the Start button down for at least CAUTION Ingesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or o...

Page 11: ...ends of the Carbon Cartridge before inserting into the Carbon Filter Housing Place the Carbon Cartridge into the Housing and screw the Housing up into the Filter Housing Cap 5 Slowly open the inlet w...

Page 12: ...drains 5 When the water flow out of the strainer stops pour the liquid bleach into the strainer Be care ful not to spill bleach onto clothing or skin You may want to add the bleach using a cup or fun...

Page 13: ...ater After a certain period of time depending upon water quality the filter has to be cleaned This is accom plished through the Flush Duration Mode During this mode the drain valve opens and flushes t...

Page 14: ...and release start but ton to view current setting Figure 7 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 8 4 After ten seconds...

Page 15: ...ter fifty minutes they are displayed in hours Table B TO SET Fd FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure...

Page 16: ...for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasi...

Page 17: ...hange the Carbon Filter Cartridge follow the steps under Install and Flush the Carbon Filter Cartridge in the Installation section of this manual CHANGING THE CAPILLARY MEMBRANE FILTER CARTRIDGE 1 Ope...

Page 18: ...exceeded it s filtration capacity Replace the Carbon Cartridge Filter Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken capillary i...

Page 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...

Page 20: ...ousing 10 1 7 1001149 Label Shroud 1 8 2090139 Cartridge Carbon Block 1 9 3080103 Screw MACH 8 32 x 1 4 1 Item Part Description Qty No Item Part Description Qty No SLTRSHD 10 1001083 Label Drain 1 11...

Page 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...

Page 22: ...984 Mounting Bracket 2 1 15 2090120 Cartridge Filter 2 x 16 1 16 2180173 Connector Slide 2 2 17 2180177 Cap End 2 2 18 0200219 O Ring 2 4 19 2190133 Tee Strainer 1 2 NPT 1 20 2090129 Screen Tee Strain...

Page 23: ...P N 1010885 07 04 WIRING DIAGRAM TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFI...

Page 24: ...zed service agency to reach the equipment location 2 Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to...