TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Unit does not have power.
The power cord is not correctly
plugged in.
Plug power cord in correctly.
The Control Display is blank.
The power cord is not correctly
plugged in.
Plug power cord in correctly.
Control Board is inoperable.
Contact your maintenance person or
Authorized Service agency.
Transformer is inoperable.
No water comes out of the
filter system
Inlet Valve closed.
Open the Inlet Valve.
Inlet Strainer is plugged.
Clean/replace Inlet Strainer.
End of the capillaries plugged.
Clean/replace Ultrafilter Cartridge.
Carbon Cartridge Filter plugged.
Replace Carbon Cartridge Filter.
Low water flow/pressure out of
system
See above.
See above.
The system may be in a flush cycle.
Wait for the flush cycle to end.
Flushing program not set correctly for
water conditions.
Decrease the flush interval and increase the
flush duration (refer to the Operation section
of this manual).
Drain Valve is stuck open.
Clean/replace/rebuild the Drain Valve.
The inlet water pressure is too low.
Boost the inlet water pressure/replace pipes.
Water tastes bad.
Storage/shipping solution not com-
pletely flushed out of system.
Flush system for a longer period of time.
Carbon Cartridge Filter has reached or
exceeded it’s filtration capacity.
Replace the Carbon Cartridge Filter.
Biological growth in pipes.
Sanitize plumbing.
Water conditions changed.
Consider installing additional filtration.
Broken capillary in Filter Cartridge.
Replace Filter Cartridge.
Flush runs continuously.
Drain Valve stuck open.
Clean/replace/rebuild the Drain Valve.
Controller sending continuous signal
to valve.
Replace the controller.
Flush runs too long.
Program duration set too long.
Re-program the unit to flush for a shorter
duration of time.
Flush occurs at time of high
water usage.
The Flush Interval is set to interfere
with water use.
Change Flush Interval/reprogram time.
Unplug unit and plug in at a time of lower
water usage.
Water splashes at drain during
flush.
Drain line not positioned properly.
Reposition the end of the drain line.
Water leaks at the ends of the
Filter Cartridge after changing
cartridges.
Cartridge end connections are not tight
enough.
Tighten with strap wrench if necessary.
O-rings not lubricated.
Lubricate O-rings with food-grade lubricant.
O-rings are split, cut, or twisted
Replace O-rings.
Water leaks from Permeate
port.
Permeate port is not tight enough
Tighten, with strap wrench if necessary.
O-ring not lubricated.
Lubricate O-ring with food-grade lubricant.
O-ring split, cut, or twisted.
Replace O-ring.
Water leaks from system fitting
or connection.
Fitting broken or loose.
Retighten or replace the fitting.
Not enough pipe thread sealant used.
Redo the fitting with the proper amount of
sealant.