Fan failure
Identify a fan failure
A flashing red LED indicates a fan failure. If this displays on
your unit, contact Technical Support for an RMA (Return
Merchandise Authorization) number and for instructions on
returning the unit to 8e6.
A steady red LED (on and not flashing) indicates an over-
heating condition, which may be caused by cables
obstructing the airflow in the system or the ambient room
temperature being too warm. Check the routing of the
cables and make sure all fans are present and operating
normally. The LED will remain steady as long as the over-
heating condition exists.