A
PPENDICES
S
ECTION
A
PPENDIX
G
544
8
E
6 T
ECHNOLOGIES
, R3000 E
NTERPRISE
F
ILTER
U
SER
G
UIDE
Step 4: Rebuild the hard drive
Once the failed hard drive has been replaced, return to the
Hardware Failure Detection window in the Administrator
console, and click
Rebuild
to proceed with the rebuild
process.
WARNING
: When the RAID array reconstruction process begins,
the Administrator console will close and the hard drive will
become inaccessible.
Step 5: Contact Technical Support
Contact Technical Support to order a new replacement hard
drive and for instructions on returning your failed hard drive
to 8e6.
Power supply failure
Step 1: Identify the failed power supply
The administrator of the server is alerted to a power supply
failure on the chassis by an audible alarm and an amber
power supply LED—or an unlit LED—on the front and rear
of the chassis.
NOTE
: A steady amber power supply LED also may indicate a
disconnected or loose power supply cord. Verify that the power
supply cord is plugged in completely before removing a power
supply.
WARNING
: Be sure the correct failed power supply has been
identified. Removing the wrong power supply will cause the
system to crash.
Step 2: Unplug the power cord
To prevent electrical shock to yourself and damage to the
unit, unplug the power cord from the failed power supply.
Summary of Contents for Enterprise Filter Authentication R3000
Page 1: ... R3000 Enterprise Filter USER GUIDE Model R3000 Release 2 1 00 Manual Version 1 02 ...
Page 2: ...ii 8E6 TECHNOLOGIES R3000 ENTERPRISE FILTER USER GUIDE ...
Page 4: ...iv 8E6 TECHNOLOGIES R3000 ENTERPRISE FILTER USER GUIDE ...
Page 578: ...APPENDICES SECTION APPENDIX H 554 8E6 TECHNOLOGIES R3000 ENTERPRISE FILTER USER GUIDE ...
Page 594: ...INDEX 570 8E6 TECHNOLOGIES R3000 ENTERPRISE FILTER USER GUIDE ...