3ware Disk Array Configuration Utility
www.3ware.com
43
8 Press F8 to rebuild. The rebuild confirmation screen will be dis-
played (see Figure 20).
Figure 20. Rebuild Confirmation Display
9 Enter Y to update configurations and exit.
Auto rebuild of a mirrored or RAID 5 array
If a hot spare is specified and the mirrored or RAID 5 array
degrades, an event notification is generated and the hot spare
dynamically replaces the failed drive in the array without user inter-
vention. Rebuild will automatically be launched as a background
process and an event notification will notify the user when the
rebuild process is complete.
3 w a r e D i s k A r r a y C o n f i g u r a t i o n
Restore Initial Values
F6
Cancel
Esc
Done
F8
Creating or destroying arrays will destroy all existing data on their
member disk drives. Using a drive for a rebuild will overwrite data on
that drive.
Data on the following drives will be destroyed.
Port 3 QUANTUM FIREBALL LM30
Update configuration and exit? [Y/N]
Summary of Contents for 3W-6800 - Escalade 6800 RAID Controller
Page 16: ...3ware Escalade Storage Switch User Guide 6 www 3ware com...
Page 26: ...3ware Escalade Storage Switch User Guide 16 www 3ware com...
Page 32: ...3ware Escalade Storage Switch User Guide 22 www 3ware com...
Page 106: ...3ware Escalade Storage Switch User Guide 96 www 3ware com...
Page 126: ...3ware Escalade Storage Switch User Guide 116 www 3ware com...
Page 137: ...Checking Array Status www 3ware com 127 Figure 50 3DM Home Display...
Page 146: ...3ware Escalade Storage Switch User Guide 136 www 3ware com Figure 56 3DM Configure Display...
Page 149: ...Mirrored Array Maintenance www 3ware com 139 Figure 57 3DM Help Display...
Page 150: ...3ware Escalade Storage Switch User Guide 140 www 3ware com...
Page 172: ...3ware Escalade Storage Switch User Guide 162 www 3ware com...