User manual
69
www.3onedata.com
Step 2: select the port in the drop - down box at the sampling port;
Step 3: fill in the value of the sample interval in the text box of the sampling interval;
Step 4: fill in the number of text boxes in the maximum number of samples;
Step 5: click the "add" button.
6.6.4.4 Alarm
Enter into Rmon alarm information configuration interface.
Index use for marking a alarm information configuration, if the index is the same as before, it will replace
previous index.
MIB point corresponds to OID.
Alarm type adopt absolute to monitor the value of MIB target. Adopt delta to monitor the change of MIB
target value when get sample two times.
When monitor MIB value reach or pass the rising threshold value, will occur event correspond to rising
event index.
When monitor MIB value reach or pass the falling threshold value, will occur event correspond to falling
event index.
(Figure 6.6.4.4)
Configure alarm group steps:
Step 1: in the serial number of the text box to fill in the alarm group number;
Step 2: select the port in the drop - down box at the sampling port;
Step 3: select the alarm parameter in the drop box of the alarm parameter;