17
6.2
Inline Splicing (3 Bank)
6.2.1 Splice opening must be that recommended for
closure used, with a minimum of 26" (66 cm)
for a 3 bank splice.
6.2.4 Adjust splice head for third connector.
6.2.5 Complete splicing and bundling.
6.2.3 Adjust splice head for second connector. Splice
per standard procedure (6.1).
6.2.2 Attach rig using single head. Splice first con-
nector following wire handling procedure Inline
Splicing (2 bank.)
26" (66 cm)
893756
Free conductors length (each cable) = minimum splice opening plus 6" (152 mm)
6.3.4 Adjust splice head for next 100-pair.
6.3
Inline Splicing (4 Bank)
6.3.1 Splice opening must be that recommended for
closure used, with a minimum of 34" (86.4 cm)
for a 4 bank splice.
Note:
This opening will require an extended sup-
port tube to attach to the cable butts; or
support tube can be attached to a
lower adjacent cable.
Free conductors length (each cable) = minimum splice opening plus 6" (152 mm)
6.3.2 Attach rig using double heads. Splice 100-pair
in both heads in this position.
6.3.3 Adjust splice head for next 100-pair.