27
6.12
Half Tapping Using 4000-D Super-Mini –
4005-DPM Super-Mate
6.12.1
Open existing tap cable (new cable.) Provide
free conductor length and slack according to
standard MS2 Procedures for Half Tapping.
Mount splicing rig with one splice head on
cables.
832611
6.12.3
When related work is complete and the
removal of the old C.O. is needed; use the
4053-PM Separator Tool to separate the old
cable that is in the Super-Mate Module.
843063
6.12.4
Crimp a new cover onto the 4000 Super-Mini
Module and place a red insulator on the
Super-Mate Module.
New C.O.
Old C.O.
FIELD
6.12.2
Lay tap (new) conductors into base of a 4000
Super-Mini Module in unilength configura-
tion. Crimp 4000 Super-Mini Module body
using the back edge of the check comb as a
temporary cover and remove cut conductors.
Lay field conductors into Super-Mini body
top, but DO NOT CRIMP.
Place Super-Mate body onto Super-Mini
body. Place corresponding through pair (old)
and lay into matching wire channels of the
Super-Mate Module.
Place cover, crimp and remove.
Old C.O.
New C.O.
FIELD
843064
4005-DPM
Insulator
893863
Old C.O.
New C.O.
FIELD
Cover
Body 4005-DPM
Body 4000-D
Base 4000-D