16
6.1.5 Place the check comb
over the base and slide
it to the left, only TIP
conductors should
show. Slide the check
comb to the right, only
RING conductors should
show. Also check for two
conductors in one channel,
for vacant channels and for
reversed pairs.
6.1.7 Select matching 25-pair groups from field
cable. Lay pairs into module bodies.
6.0
Application
Note:
Splice modules so that equal number of
modules will fall in each bank.
6.1
Inline Splicing (2 Bank)
6.1.1 Splice opening must be that recommended for
closure used, with a minimum of 17" (43.2 cm)
for a 2 bank splice.
893745
6.1.6 Place body into
leaf spring
tracks of both
splice heads
with cut corner
to left of rear
splice heads.
832600
6.1.10 Tie down splice bundle in center first,
working any slack toward both cable butts.
75473
6.1.8 Check for
correct placement
of pairs.
6.1.9 Place covers and
crimp. Repeat
process for remaining
25-pair groups.
832601
893745
893756
17" (43.2 cm)
Free conductors length (each cable) = 1.5 X splice opening
4"
4"
Note: Splice heads set 4" (10.2 cm) from butt of group being spliced
and slightly higher.
893756
6.1.3 When splicing with Super-Mini Module, splice
head adapter must be used.
Select back bottom 25-pair group from C.O.
cable.
Lay pairs into module base on C.O. side of
splice opening.
For easy group ID, place odd groups to left
side, even groups to right side.
6.1.2 Attach rig using double heads.
Center heads in opening.
6.1.4 Select next back bottom 25-pair group from
C.O. cable.
Lay pairs into module base on field side of
splice opening.
75469
Field
C.O.
893756
893756
Field
C.O.
75469
Field
893756
75469
C.O.