14
Installation and Set-Up
(Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles
box sizes up to 620 mm [24.5 inch] maximum
height. If larger capacity is needed, the machine
can be adjusted to accommodate boxes up to
725 mm [28.5 inch] high. Refer to "Special Set-
Up Procedure – Box and Machine Bed Height
Range", page 31. Note – Adjusting machine
to accommodate 725 mm [28.5 inch] high
boxes also increases minimum box size to
170 mm [6.8 inch].
Note – Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems or
other electrical requirements compatible with
local practice.
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
BUMPER SUPPORTS (Upper Drive Assembly)
Raise and lock the upper drive assembly into its
raised position. See "Operation – Mechanical
Latch", page 18.
Install the two bumper supports, one on each side
column using lower holes in bracket as shown in
Figure 2-6. (The upper set of holes allows the upper
drive assembly to return to a lower position.
However, this minimum position can only be used if
the taping heads are adjusted to apply 50 mm
[2 inch] long tape legs.)
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box and "On/Off" switch
are located on the lower left side of the machine
frame. See Figure 3-1. If desired, for operator
convenience, the "On/Off" switch can be
relocated to the right side of the machine frame.
A standard three conductor power cord with plug
is provided at the back of the electrical control
box for 115 Volt, 60 Hz., 3.8 Amp electrical
service. The receptacle providing this service
shall be properly grounded. Before the power
cord is plugged into 115 Volt, 60 Hz outlet make
sure that all packaging materials and tools are
removed from the machine. Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16 ], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
WARNING – To prevent shock and
fire hazard: Position extension
cord where it will be out of the way of foot
or vehicle traffic. Extension cord is only
for temporary use – do not use for a
permanent installation.
Figure 2-6 – Bumper Supports
Note – Interference and damage to the taping
heads may occur if the upper mounting bracket
holes are used with the taping heads at the
standard setting (70 mm [2.75 inch] tape legs).
Summary of Contents for Matic 700r
Page 33: ...28 THIS PAGE IS BLANK ...
Page 45: ...40 THIS PAGE IS BLANK ...
Page 46: ...41 700r Random Case Sealer Frame Assemblies ...
Page 47: ...42 700r Random Case Sealer Figure 2807 ...
Page 49: ...44 700r Random Case Sealer Figure 3437 ...
Page 51: ...46 700r Random Case Sealer Figure 3439 ...
Page 53: ...48 700r Random Case Sealer Figure 5670 ...
Page 55: ...50 Figure 5916 1 of 2 700r Random Case Sealer ...
Page 57: ...52 Figure 5916 2 of 2 700r Random Case Sealer ...
Page 59: ...54 700r Random Case Sealer Figure 5917 ...
Page 61: ...56 Figure 5918 1 of 2 700r Random Case Sealer ...
Page 63: ...58 700r Random Case Sealer Figure 5918 2 of 2 ...
Page 65: ...60 700r Random Case Sealer Figure 5919 ...
Page 67: ...62 700r Random Case Sealer Figure 5920 ...
Page 69: ...64 700r Random Case Sealer Figure 5921 ...
Page 71: ...66 Safety and Information Labels 700r Random Case Sealer ...