24
Maintenance
(Continued)
WARNING – Turn off electrical power and air supply and disconnect power cord from electrical
supply before beginning maintenance. If power cord is not disconnected, severe injury to
personnel could result.
Circuit Breaker
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical enclosure on the side of the
machine frame just below the machine bed, the
circuit breaker has been pre-set at 2.2 amps and
requires no further maintenance.
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1.
Determine cause of overload and correct.
2.
Remove electrical enclosure cover.
3.
Press "Reset" and then "Start" buttons on
circuit breaker. If circuit breaker will not
reset, wait 2 minutes and retry.
4.
Replace cover.
5.
Plug in machine.
6.
Press machine "On" button to resume case
sealing.
Knife Replacement, Taping Head
See Section
II
, "Maintenance – Blade (Knife)
Replacement", page 9.
Summary of Contents for Matic 700r
Page 33: ...28 THIS PAGE IS BLANK ...
Page 45: ...40 THIS PAGE IS BLANK ...
Page 46: ...41 700r Random Case Sealer Frame Assemblies ...
Page 47: ...42 700r Random Case Sealer Figure 2807 ...
Page 49: ...44 700r Random Case Sealer Figure 3437 ...
Page 51: ...46 700r Random Case Sealer Figure 3439 ...
Page 53: ...48 700r Random Case Sealer Figure 5670 ...
Page 55: ...50 Figure 5916 1 of 2 700r Random Case Sealer ...
Page 57: ...52 Figure 5916 2 of 2 700r Random Case Sealer ...
Page 59: ...54 700r Random Case Sealer Figure 5917 ...
Page 61: ...56 Figure 5918 1 of 2 700r Random Case Sealer ...
Page 63: ...58 700r Random Case Sealer Figure 5918 2 of 2 ...
Page 65: ...60 700r Random Case Sealer Figure 5919 ...
Page 67: ...62 700r Random Case Sealer Figure 5920 ...
Page 69: ...64 700r Random Case Sealer Figure 5921 ...
Page 71: ...66 Safety and Information Labels 700r Random Case Sealer ...