background image

IMPORTANT:

MOUNT APPLIANCE SO THAT THE

CONTROL PANEL IS LOCATED TO

THE FRONT OF THE FIXTURE.

MASTER

CONTROL

PANEL

SCREWDRIVER

COUNTERTOP

WELLSLOK

GASKET

FLANGE

WATER SUPPLY

1/4 NPT

SOLENOID

OUTLET BOX

FRONT PANEL

   CUTOUT

TOP CUTOUT

33 7/8

(860)

5

(127)

4 1/8
(105)

29 1/2

(749)

42 3/4
(1086)

3 1/8

(79)

PHASE

AMPS

11.9

10.3

11.9

10.3

L3

L2

L1

FROM UNIT TO THE NEAREST SURFACE

MINIMUM CLEARANCE REQUIRED

4 1/8
(105)

6 3/4
(171)

(25)

1

1

(25)

FRONT

BOTTOM

SIDE

BACK

CLEARANCES

NOTE: MOD-327TDM/AF UNITS ARE SHIPPED THREE PHASE

AND ARE FIELD CONVERTIBLE TO SINGLE PHASE. THE

DRAIN MANIFOLD WITH 1 INCH INTERNAL FPT IS SUPPLIED

WITH THE UNIT.

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

OUTLINED BELOW UPON INSTALLATION:

1. Required Installation Clearances:

Wooden and Metal Installation: DO NOT install closer than

4 1/8 inches to front wall, 1 inch to back and side walls,

and 6 3/4 inches to surface below the unit.

2. Unit shall be accessible for servicing from the bottom.

3. If storage is to be used underneath the unit, it is

recommended that a baffle be placed 8 1/2 inches below

the unit to avoid contact with elevated temperatures.
TO FABRICATE:

1. Lay out "cutout" dimensions on countertop and front apron. 

2. Lay out and fabricate control panel holes in counter

apron using the control box as a template.

3. Cut out holes.

TO INSTALL:

IMPORTANT - DO NOT disconnect lead wires from the

Master Control Panel when making installation.

1. Tilt and pass Control Panel and electrical box through

the countertop cutout, then through the apron cutout.

Lower modular section into countertop cutout and position.

RECOMMENDATION: Before final seating of modular section

to countertop, apply a bead of silicone adhesive/sealant to

the supplied gray gasket material on the underside of the

mounting flange.

2. From underneath, insert screwdriver into slots in the

Wellslock frame and twist the ears outward (clockwise) as

required to secure flange tightly to countertop.

3. Mount Control Box to apron cutout as shown in drawing.

4. Mount Control Panel onto the electrical box using the

screws supplied.

5. Remove any excess gasket or sealant material from the

outer flange.

PRODUCT DIMENSIONS

CUTOUT DETAILS

75

°

C

75

°

C

14 AWB Cu

14 AWB Cu

17.9
20.6

11.9

10.3

4950

3720

208
240

MOD-327TDM

MOD-327TDM

RATING

FIELD WIRING GAUGE

TEMP.

SINGLE

AMPS PER LINE 3 PHASE

WATTS

VOLTS

MODEL

ELECTRICAL

WELLS/BLOOMFIELD * VERDI, NV

MOD 327TDM/AF

BUILT-IN MODULAR WARMERS

INSTALLATION INSTRUCTIONS

300748-2   REV (-)

TO PLUMB:

1. A drain manifold complete with valve is supplied on all Model

'TDM' units. Location of valve handle is at the discretion of the

fabricator (see drawing).

2. Connect 1'' drain connection to a suitable drain line.

3. Connect 1/4 NPT water supply to the Solenoid valve in the

Outlet Box. NOTE: Maximum water pressure is 120 psi and

maximum temperature is 120

°

F. A backflow prevention valve is

installed in the water fill system. Check local codes for any

additional plumbing requirements.

TO WIRE:

1. Final connection is accomplished by bringing proper power

supply leads (see 'WIRING REQUIREMENTS label') through 1''

conduit knockout to terminal block supplied within the Master

Control Panel. Check nameplates for voltage and phase.

NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND

ELECTRICAL CODES.

INSTALLATION INSTRUCTIONS

10 AWB Cu

10 AWB Cu

3 PHASE

1 PHASE

1'' CONDUIT

CONNECTION

1'' FPT

EACH END

OF MANIFOLD

1/4'' FPT

WATER LINE

CONNECTION

43 1/2
(1105)

2 1/4

(57)

30 9/16

(776)

35

(889)

6 1/4
(159)

14

(356)

1 3/4

(44)

7 3/4
(197)

9 3/4

(248)

WITH AUTO WATER FILL

INCHES

(MM)