background image

3M Touch Systems Proprietary Information

2

Installation Addendum

Product safety information

DANGER

To reduce the risks associated with fire and explosion which, if not 
avoided, will cause death or serious injury and/or property damage:

Do not open the ET unit (or hatch, if applicable) while the circuit is live 
unless the area is known to be non-hazardous.
Do not use an external keyboard or mouse unless the area is known to be 
non-hazardous.
Do not operate the ET unit’s OSD switches, DIP switch, KVM extender 
remote board, or potentiometer on the KVM extender remote board unless 
the area is known to be non-hazardous.
Do not disconnect equipment unless power has been switched off or the 
area is known to be non-hazardous.
Do not replace the fuse unless the power has been disconnected and the 
area is known to be non-hazardous.
Do not use the ET unit in Class I, Division 1;  Zone 0; or Zone 1 hazardous 
locations.

WARNING

To reduce the risks associated with electrical shock, fire, or 
explosion which, if not avoided, could result in death or serious 
injury and/or property damage:

Follow all product and accessory installation instructions, including 
instructions for mounting the unit with a NEMA 4X panel gasket (ships with 
all ET 355 monitors) and instructions that accompany the NEMA 4X hatch 
kit.
The procedures described in this document should be performed only by 
trained personnel. Failure to perform all operations correctly could 
damage the unit and invalidate the warranty.
For servicing or other procedures not described in this document, in the 
ET 350 Monitor User’s Installation Guide, or in other ET 35X instructions, 
return the ET unit to 3M Touch Systems for servicing.
Read and understand all safety information before installing and using the 
ET unit.
Engineer the installation of the ET unit to take into account the operating 
environment (e.g., hazardous location, shock/vibration factors).
Properly install the ET unit with a NEMA 4X gasket that is clean, 
undamaged, and effective.
Do not modify the ET unit.
Do not substitute components. Substitution of components may impair 
suitability for a Class I, Division 2; Class II, Division 2; or Zone 2 hazardous 
location.
When replacing a fuse or other part, use a part of the type and rating 
specified by 3M Touch Systems.
Provide a clean, reliable ground.
Use locking devices on connectors.
To ensure compliance with electrical codes and safe operation of the 
monitor, have a licensed journeyman electrician familiar with local codes 
perform all wiring and installation tasks.
When connecting power with fixed field wiring in the NEMA 4X hatch, the 
field wiring must be double insulated. A clear, flexible insulator (supplied) 
must cover the portion of the cable that is not double insulated when 
connecting to a terminal strip connector.
After making an opening in the NEMA 4X hatch, make sure that there are 
no metal shavings in the hatch.
When installing the ET unit, ensure that specifications for supply circuit 
overcurrent protection and wiring are not exceeded.
Choose listed (UL) conduit hub or Notified Body Certified gland rated 
NEMA 4X/IP66 that is suitable for use in hazardous locations, and provide 
adequate strain relief for wiring.
Properly install the ET unit so that it is environmentally sealed to the 
NEMA 4X/IP66 standard. Do not use the ET unit with mounting options 
that are not rated for NEMA 4X/IP66 in environments that require such a 
seal. Use the NEMA 4X hatch with ET 35X monitors with heater.
If a KVM extender is used with the ET unit, the KVM local unit should be 
located in an area known to be non-hazardous.
Do not use flammable or combustible cleaners on or near the ET unit.

WARNING

To reduce the risks associated with electrical shock or fire which, if 
not avoided, could result in death or serious injury and/or property 
damage:

If the ET unit is mounted using a NEMA 4X panel gasket, install the unit in 
a Listed (UL) enclosure.
If the ET unit will be used in corrosive environments, it is the responsibility 
of the user to test and evaluate the unit in those environments. The 
monitor, as shipped, has not been evaluated for use in excessively 
corrosive environments. Using it in such environments, without evaluation 
and testing, may lead to unsafe conditions.

WARNING

To reduce the risks associated with electric shock and/or burn-
related injury that could result in death or serious  injury and/or 
property damage:

Avoid contact with connectors on power terminal strip unless the power 
has been disconnected.
Avoid exposed electrical contacts inside the ET unit.

WARNING

To reduce the risks associated with electrical shock which, if not 
avoided, could result in death or serious injury and/or property 
damage:

Make sure that the ground potential difference between the ET unit and 
the host computer is less than 2V.
Before removing the ET unit from its mounting or performing any other 
service to the monitor, disconnect power to the unit.
Provide adequate strain relief for all field wiring in accordance with Class 
I, Division 2 wiring methods Article 501-4(b) of the National Electric Code, 
NFPA 70 for installations in the U.S., or as specified in Section 18-1J2 of 
the Canadian Electrical Code for installations within Canada and in 
accordance with the authority having jurisdiction.

WARNING

To reduce the risks associated with electrical shock or mechanical 
function which, if not avoided, could result in death or serious injury 
and/or property damage:

Apply a “safe touch” setting, especially if the ET unit is running an 
application or is in a setting where safety is a concern.
Do not use a non-Windows operating system screen saver that may affect 
the “safe touch” setting and could in turn cause connected peripheral 
equipment to start or stop inadvertently.
Set the safe touch setting correctly, with the number of minutes entered 
for the Windows operating system’s energy saver being at least one 
minute greater than the time entered for the Windows operating system 
screen saver.
If your ET unit has a display power management system (DPMS) that is 
configurable from the display’s on-screen Utility menu, do not turn off the 
DPMS.

WARNING

To reduce the risks associated with electric shock and/or burn-
related injury that could result in death or serious injury and/or 
property damage:

Do not open the power supply in the ET unit. It contains hazardous 
voltage/hazardous energy. The power supply has no user-serviceable 
parts or adjustments inside.

WARNING

To reduce the risks associated with mechanical function which, if not 
avoided, could result in property damage:

Do not operate the ET unit in conditions outside of the operational 
specifications.

Summary of Contents for Dynapro ET 355 Monitor HL

Page 1: ...s than or equal to 85 C Where combustible dust is not normally in the air in ignitable concentrations dust accumulations are normally insufficient to interfere with normal operation of electrical equi...

Page 2: ...unit so that it is environmentally sealed to the NEMA 4X IP66 standard Do not use the ET unit with mounting options that are not rated for NEMA 4X IP66 in environments that require such a seal Use the...

Page 3: ...the risks associated with muscle strain which if not avoided may result in minor or moderate injury Avoid using the ET unit for long periods of time without breaks CAUTION To reduce the risks associat...

Page 4: ...ijk om op te tillen Gefahr des berhebens adottate le necessarie misure di protezione Symbol Meaning Caution Item is susceptible to electrostatic discharge ESD damage if proper precautions are not take...

Page 5: ...ith the optional hatch kit All of these documents and the software guides are available for download from www 3Mtouch com Guidelines for maintaining the ET 355 Monitor HL To minimize factors that migh...

Page 6: ...tant All options including VGA and serial cables must be considered in the end product Wiring methods must be considered in the end product Consider conducting a heating test in the end product of whi...

Page 7: ...SA and Canada General information Tel 800 667 0374 toll free Fax 604 521 4629 E mail etsales mmm com Web site www 3Mtouch com Customer service Tel 800 667 0374 toll free Fax 604 521 4629 E mail 3MTScu...

Page 8: ...ler la garantie Pour tout entretien ou toute proc dure qui n est pas d crite dans ce document dans le Guide d installation du moniteur ET 350 ou dans les autres consignes ET 35X retourner l appareil 3...

Page 9: ...ombre de minutes entr es pour l conomiseur d nergie du syst me d exploitation Windows doit tre au moins une minute de plus que le temps entr pour l conomiseur d cran du syst me d exploitation Windows...

Page 10: ...dez de la garant a Para obtener instrucciones sobre c mo darle servicio al equipo u otros procedimientos que no est n descritos en este documento en la Gu a de instalaci n de monitores ET 350 para el...

Page 11: ...seguridad t ctil y pudieran a su vez ocasionar que los dispositivos perif ricos conectados se enciendan o se apaguen inesperadamente Establezca la configuraci n de seguridad t ctil correctamente que e...

Page 12: ...ere procedures die niet worden beschreven in dit document in de Installatiehandleiding voor de gebruiker van de ET 350 monitor of in andere instructies voor de ET 35X dient u de ET eenheid retour te s...

Page 13: ...n randapparatuur onbedoeld in werking kan treden of kan stoppen Stel de safe touch instelling correct in waarbij het ingevoerde aantal minuten voor de energiebesparende functie van het Windows besturi...

Page 14: ...Ma nahmen nicht korrekt ausgef hrt werden k nnen Besch digungen an der Einheit entstehen und die Garantie kann ung ltig werden Zur Durchf hrung von Wartungsarbeiten und anderen nicht in diesem Handbu...

Page 15: ...ie keinen Bildschirmschoner eines anderen Betriebssystems als Windows da die Einstellung Sichere Ber hrung beeintr chtigt werden k nnte und sogar angeschlossene Peripherieger te ungewollt ein oder aus...

Page 16: ...o del monitor con una tenuta per pannelli NEMA 4X fornita di serie con tutti i monitor ET 355 nonch le istruzioni fornite con il kit per alloggiamenti NEMA 4X kit di montaggio opzionale per il monitor...

Page 17: ...le attrezzature attenersi alle indicazioni riportate di seguito Configurare un impostazione safe touch specialmente se il monitor ET o il computer gestiscono applicazioni specifiche o se sono installa...

Page 18: ...com 355 HL ET 355 HL I 2 501 4 b 70 18 1J2 ET OSD ET DIP KVM KVM ET I 1 0 1 NEMA 4X 355 NEMA 4X 355 ET 350 ET 35X 3M Touch Systems ET NEMA 4X ET I 2 II 2 2 3M Touch Systems NEMA 4X 3M Touch Systems Pr...

Page 19: ...ET 35X KVM ET KVM ET ET NEMA 4X UL ET ET ET 2V ET I 2 501 4 b 70 18 1J2 safe touch ET Windows safe touch Windows Windows ET DPMS Utility DPMS ET 350 ET 355 HL ET MSDS ET 3M Touch Systems Proprietary...

Page 20: ...ET ET ET 3M Touch Systems Proprietary Information 20 Intended Use and Product Safety Information Russian...

Page 21: ...Zone 1 ET NEMA 4X ET 355 ET 355 NEMA 4X ET350 ET 35X ET 3M Touch Systems ET ET NEMA 4X ET ET Class I Division 2 Class II Division 2 Zone 2 3M Touch Systems NEMA 4X NEMA 4X ET UL Notified Body Certifi...

Page 22: ...ET DPMS DPMS ET 350 ET 355 HL ET MSDS ET ET ET ET 3M Touch Systems Proprietary Information 22 Intended Use and Product Safety Information Chinese...

Page 23: ...stems express written consent User should contact its sales representative if User s opportunity involves a medical device application Important notice to purchaser Specifications are subject to chang...