15
The LED lights are red but have blue tips on the ends.
(This means the sensor box is not connected to the SRL carabiner.)
1. Carabiner is sleeping, turn gate 1-2 times to wake up carabiner. Lights will turn fully red.
2. Do Bluetooth pairing procedure. See section 4.1.
3. Is the carabiner battery completely dead?
�
Replace with a new battery per section 4.2.
�
When replacing battery check if the battery connector is broken (seen as not fully attached to the
circuit board when battery door is opened)?
4. Red Tag for OP Manufacturer
�
OP Manufacturer—Replace with new SRL/carabiner.
· Call 3M if above actions do not work.
The LED lights are red with yellow tips on the ends of the lights.
(This means the carabiner battery is low.)
1. Confirm carabiner battery is low by seeing red blinking light on carabiner once every three seconds. Follow
procedure in section 4.2 for carabiner battery replacement.
�
Be careful to not pull battery holder off circuit board.
�
If you replace your carabiner battery frequently (more than once per month) there may be something keeping the
carabiner gate open, call 3M to discuss.
2. Red Tag for OP Manufacturer if above actions do not work.
�
OP Manufacturer—Call 3M for further analysis if carabiner needs to be replaced.
Only one LED strip is lighting up.
1. Check connection on sensor box.
2. Red Tag for OP Manufacturer
�
OP Manufacturer—Replace LED strip.
· If that doesn't work call 3M to assess if new sensor box is required.
The LED lights are flashing yellow (once every 3 seconds).
(This means something is too close to the sensor box lens or that the system has detected an
electronic fault.)
1. Check if there is an obstruction in front of the lens (closer than 15cm) or if there is debris on the sensor box lens.
Remove the obstruction and/or clean lens. If this does not stop the yellow flashing then see below step.
2. Pull the power cord from the sensor box then plug power back in. If at power up there is a series of descending
pitch tones instead of a chirp from the audible alert and the yellow flashing is still present, then there is an
electronic fault in the sensor box.
3. Red Tag for OP Manufacturer
�
OP Manufacturer—Call 3M to discuss.