Table 2 – Inspection and Maintenance Log
Model Number (Serial Number):
Date Purchased:
Date of First Use:
···
;
This product must be inspected by the user before each use. Additionally, a Competent Person other than the user must
inspect this equipment at least once each year.
···
Component
Inspection Procedure
Inspection Result
Pass
Fail
SRD - General
(Figure 14.1)
Inspect for loose bolts and bent or damaged parts.
Inspect Housing (A) for distortion, cracks, or other damage.
Inspect the Swivel Eye (B) for distortion, cracks, or other damage. The
Swivel Eye should be attached securely to the SRD, but should pivot freely.
The Lifeline (C) should pull out and retract fully without hesitation or
creating a slack line condition.
Ensure device locks up when lifeline is jerked sharply. Lockup should be
positive with no slipping.
Look for signs of corrosion on the entire unit.
Connectors
(Figure 14.2)
Inspect all SRD connectors for signs of damage and corrosion. Verify that
all connectors are working properly. Where present: Gates (A) should open,
close, lock, and unlock properly; Swivel Eyes (B) should rotate without
interference; and locking buttons and pins should function correctly.
Web Lifeline
(Figure 14.3)
Inspect the webbing for Cuts (A), Frays (B), broken fibers, tears, abrasion,
Heavy Soiling (C), mold, Burns (D), and discoloration. Inspect the lifeline
stitching for pulled or cut stitches, since broken stitches may indicate that
the product has been impact-loaded and must be removed from service.
Energy Absorber (Figure 15)
Verify that the integral energy absorber has not been activated. Verify that
the Lifeline Cover (A) has not pulled out from the Energy Absorber Cover
(B) on either end. None of the Energy Absorber Webbing (C) should be
exposed. The Energy Absorber Cover should also be secure and free of
Tears (D) or other damage.
Labels (Figure 13)
All labels are present and fully legible.
Fall Protection Equipment
Additional Fall Protection equipment that is used with the product is
installed and inspected per the manufacturer instructions.
···
;
If the product fails an inspection procedure, then the product fails overall inspection. If the product fails inspection, remove
it from service immediately. Clearly tag the product “DO NOT USE”. See Section 5 for more information.
···
Inspection Type:
User
Competent Person
Overall Inspection Result:
Pass
Fail
Inspected By:
Date of Inspection:
Signature:
Next Inspection Due:
···
Additional Notes:
Summary of Contents for DBI SALA NANO-LOK 3101526
Page 18: ...18 Figure 13 RFID Tag Location Figure 14 Product Labels 2Æ A C A B C B ...
Page 19: ...19 Figure 14 Product Labels A B C D B D B D A C ...
Page 39: ...39 Figura 13 Ubicación de la etiqueta RFID Figura 14 Etiquetas del producto 2Æ B A C A B C ...
Page 40: ...40 Figura 14 Etiquetas del producto A B C D B D B D A C ...
Page 43: ......