3. Wrap a 3” (7.6 cm) 

long piece of PTFE tape 
to the right (clockwise) 
around the 3/8” MNTP 
threads of the fittings. 
Wrap tightly so that 
it conforms to the 
threads of the fitting 
and overlaps about 
1/2”. (Figure 3)  

Do 

not wrap 3/8” or 1/2” 
compression threads 
with tape.

4. Screw one fitting 

into the filter outlet 
and the other fitting 
into the filter inlet 
(both are labeled on 
filter head assembly.) 
Tighten both fittings 
with a wrench. 

Do 

not overtighten

.  

Overtightening may 
result in a cartridge 
crack which may 
lead to fluid leaking

 

(Figure 4)

5. Remove the two 

screws at top of head 
assembly.  Position 
either inlet fitting or 
outlet fitting through 
large hole in bracket 
and replace these two 
screws.  Filter head 
is now mounted and 
ready for plumbing. 
(Figure 5)

6. Measure down from 

filter inlet fitting about 
1” (3 cm) and mark 
existing cold water 
tubing.  From this 
mark, measure up 
8” (20 cm) and mark 
tubing.  This is the 
section of tubing to 
be removed.  If neces-
sary, because of tight 
situations, additional 
tubing may be cut 
away. (Figure 6)

IMPORTANT INSTALLATION INSTRUCTIONS (Continued)

Figure 8

Figure 9

Figure 10

Figure 3

Figure 6

7. Turn off cold water 

supply valve and open 
cold water tap to 
relieve system pres-
sure.  Cut cold water 
tubing using a tube 
cutter or razor knife.  
Do not use a hacksaw, 
etc.  Place a pan under 
it to catch any water 
present. (Figure 7)

8. Two compression 

fittings are required 
for tube ends.  Check 
tube size.  Use 3/8” 
x 3/8”, 1/2” x 3/8”, 
or 5/8” x 3/8” com-
pression fittings as 
required.  Slip nut 
and ferrule on water 
tubing as shown 
and fasten fittings in 
place. (Figure 8)

9.  Cut two lengths of 

3/8” soft copper 
tubing and bend to 
shape as shown. 
Bend tubing to form 
gentle curves rather 
than sharp bends. 
(Figure 9) 

10. Connect both pieces 

of tubing to filter and 
water tube as shown 
with compression 
fittings. 

Do not over-

tighten nuts

(Figure 10)

11. Open the cold water 

faucet to expel 
trapped air.  Open 
the supply valve to 
allow water to enter 
the filter.  If any leaks 
occur, close the sup-
ply valve and open 
the faucet to relieve 
the pressure, then 
gently tighten the 
fitting that is leak-
ing.  Flush at least 2 
gallons through filter 
before use (approxi-
mately 1 minute of 
flushing).  Water may 
run cloudy due to air 
but will clear quickly.

Do not crimp copper tubing.

IMPORTANT NOTE

Compression Fittings

Compression 
Fittings

PTFE Tape

Figure 4

Figure 5

Cold Water Line

1”

8”

Figure 7

Nut

Ferrule

Compression Fitting

Compression Fitting

Ferrule

Nut

Ferrule

Nut

Nut

Ferrule

Tubing

Head

To existing faucet 

(cold water side only)

Summary of Contents for Aqua-Pure AP510

Page 1: ...Installation and Operating Instructions For AP510 Full Flow Drinking Water System Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenance instructions...

Page 2: ......

Page 3: ...ove filter cartridge when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install on hot water supply lin...

Page 4: ...lter to install car tridge Determine a desirable location for the filter installation and inlet connec tion Attach the mounting bracket to appropriate mounting bosses on filter head with the self tapp...

Page 5: ...pen cold water tap to relieve system pres sure Cut cold water tubing using a tube cutter or razor knife Do not use a hacksaw etc Place a pan under it to catch any water present Figure 7 8 Two compress...

Page 6: ...water consumption 3M PURIFICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PAR...

Page 7: ...r as de suministro de agua La m xima temperatura del agua para el correcto funciona miento de este sistema de filtro es 100 F 37 8 C No lo instale si la presi n del agua excede las 125 psi 862 kPa Si...

Page 8: ...Elija el lugar donde desee instalar el filtro y hacer la conexi n de entrada Acople el soporte de montaje a los salientes de montaje de la cabeza del filtro con los tornillos autorroscantes provistos...

Page 9: ...or de tubos o un c ter No utilice una sierra para metales etc Coloque una bandeja debajo de ste ya que puede caer agua Figura 7 8 Se necesitan dos acce sorios de compresi n para los extremos de los tu...

Page 10: ...variar seg n las condiciones del agua local y el consumo de agua 3M PURIFICATION INC NO OTORGA OTRAS GARANT AS NI CONDICIONES EXPRESAS NI IMPL CITAS INCLUYENDO PERO NO LIMITANDO CUALQUIER GARANT A IM...

Page 11: ...s zones o la temp rature ambiante est sup rieure 43 3 C 110 F Ne pas installer sur une conduite d eau dont la pression est sup rieure 862 kPa 125 psi Si la pression est sup rieure 552 kPa 80 psi il es...

Page 12: ...trante D terminer l endroit o seront install s le filtre et le raccordement l arriv e d eau Fixer le support de fixation aux endroits pr vus cette fin sur la t te du filtre l aide des vis autotaraudeu...

Page 13: ...pour recueillir l eau qui pourrait s couler figure 7 8 Deux raccordements compression doivent tre plac s aux extr mit s du tuyau V rifier la taille du tuyau Utiliser des adap tateurs de raccordement c...

Page 14: ...eau locales ou des quantit s d eau consomm es 3M PURIFICATION Inc N OFFRE AUCUNE AUTRES GARANTIE OU CLAUSE EXPLICITES OU IMPLICITES Y COMPRIS MAIS SANS S Y LIMITER TOUTE GARANTIE OU CLAUSE IMPLICITE D...

Page 15: ...NOTES NOTAS NOTES...

Page 16: ...rk of 3M Company used under license 2011 3M Company All rights reserved INSTR2002 1111 3M Purification Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 222 7880 Worldwide 203 237 5541 Fax...

Reviews: