background image

Parts and Materials Included:

1.  Two Self-tapping Screws
2. Mounting 

Bracket

3. Head 

Assembly

4.  Cartridge Model AP517

Tools and Parts Required (not included):

• Choice 

of: 

  Two #10 Machine Screws (length to suit), Two Washers and 
  Two #10 Machine Screw Nuts 
  OR Two #10 Sheet Metal Screws and Two Washers
  OR Two Wood Screws
•  Two 3/8” MNPT x 3/8” or 1/2” Compression  

 

  Fittings Depending on Existing Plumbing
• PTFE 

Tape

• Adjustable 

Wrench

•  Drill (Cordless Recommended)
•  Phillips Head Screwdriver
•  Razor Knife Or Tube Cutter
•   3/8” soft copper or plastic tubing, 5’ length

Empty contents of package and identify all parts as shown in 
diagram. Read all instructions carefully before attempting to start 
installation.  

Before starting, close shut-off valve on kitchen 

cold water line.

GETTING STARTED

1

2

4

3

Your new Aqua-Pure

®

 AP510 Full Flow Drinking Water System will reduce chlorine tastes and odors, particulate and 

scale from your drinking water. The filter installs under the sink on the cold water line and uses the existing faucet.  The 
AP510 features its own automatic shut-off, thereby eliminating the need for any external valves. The installation proce-
dure covered in this manual requires the removal of a section of the cold water tube. Soft copper tubing and compres-
sion fittings should be purchased locally to complete the installation.

1.  Position the filter by holding it against the right hand side of the cabinet wall 

underneath the sink. Allow at least 3” (7.6 cm) beneath the filter to install car-
tridge. Determine a desirable location for the filter installation and inlet connec-
tion. Attach the mounting bracket to appropriate mounting bosses on filter head 
with the self-tapping screws supplied. (Figure 1)

2.  For installation using machine screws and nuts, remove drawer from adjacent 

cabinet and drill two 7/32” diameter holes through cabinet wall. Fasten filter 
bracket to wall with screws, nuts and washers. Use washers on both sides of the 
wall. Mounting to the cabinet side wall gives the filter good, rigid support. (Figure 
2)  For installation using sheet metal screws, simply prick punch at marked loca-
tion (Step 1), position bracket in place, and install screws with screwdriver.

IMPORTANT INSTALLATION INSTRUCTIONS

Figure 1

CAUTION

To reduce the risk associated with property damage due to water leakage:

 • 

Do not install on hot water supply lines

.  The maximum operating water 

temperature of this fi lter system is 100°F (37.8°C).

 • 

Do not

 use a torch or other high temperature sources near fi lter system, 

cartridges, plastic fi ttings or plastic plumbing. 

IMPORTANT NOTES

  •  Allow a minimum of 3” (7.6 cm) clear space under fi lter to facilitate 

cartridge change.

WARNING

To reduce the risk associated with a hazardous voltage due to an installer drill-
ing through existing electric wiring or water pipes in the area of installation:

 • 

Do not

 install near electric wiring or piping which may be in the path of a 

drilling tool when selecting the position to mount the fi lter bracket.

Figure 2

Note:

 If the filter is not connected to the head assem-

bly upon opening this carton, please refer to the 
“Filter Cartridge Replacement Instructions” Section, 
Step 3.

Summary of Contents for Aqua-Pure AP510

Page 1: ...Installation and Operating Instructions For AP510 Full Flow Drinking Water System Installer Please leave manual with homeowner Homeowner Please retain for operation and future maintenance instructions...

Page 2: ......

Page 3: ...ove filter cartridge when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install on hot water supply lin...

Page 4: ...lter to install car tridge Determine a desirable location for the filter installation and inlet connec tion Attach the mounting bracket to appropriate mounting bosses on filter head with the self tapp...

Page 5: ...pen cold water tap to relieve system pres sure Cut cold water tubing using a tube cutter or razor knife Do not use a hacksaw etc Place a pan under it to catch any water present Figure 7 8 Two compress...

Page 6: ...water consumption 3M PURIFICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PAR...

Page 7: ...r as de suministro de agua La m xima temperatura del agua para el correcto funciona miento de este sistema de filtro es 100 F 37 8 C No lo instale si la presi n del agua excede las 125 psi 862 kPa Si...

Page 8: ...Elija el lugar donde desee instalar el filtro y hacer la conexi n de entrada Acople el soporte de montaje a los salientes de montaje de la cabeza del filtro con los tornillos autorroscantes provistos...

Page 9: ...or de tubos o un c ter No utilice una sierra para metales etc Coloque una bandeja debajo de ste ya que puede caer agua Figura 7 8 Se necesitan dos acce sorios de compresi n para los extremos de los tu...

Page 10: ...variar seg n las condiciones del agua local y el consumo de agua 3M PURIFICATION INC NO OTORGA OTRAS GARANT AS NI CONDICIONES EXPRESAS NI IMPL CITAS INCLUYENDO PERO NO LIMITANDO CUALQUIER GARANT A IM...

Page 11: ...s zones o la temp rature ambiante est sup rieure 43 3 C 110 F Ne pas installer sur une conduite d eau dont la pression est sup rieure 862 kPa 125 psi Si la pression est sup rieure 552 kPa 80 psi il es...

Page 12: ...trante D terminer l endroit o seront install s le filtre et le raccordement l arriv e d eau Fixer le support de fixation aux endroits pr vus cette fin sur la t te du filtre l aide des vis autotaraudeu...

Page 13: ...pour recueillir l eau qui pourrait s couler figure 7 8 Deux raccordements compression doivent tre plac s aux extr mit s du tuyau V rifier la taille du tuyau Utiliser des adap tateurs de raccordement c...

Page 14: ...eau locales ou des quantit s d eau consomm es 3M PURIFICATION Inc N OFFRE AUCUNE AUTRES GARANTIE OU CLAUSE EXPLICITES OU IMPLICITES Y COMPRIS MAIS SANS S Y LIMITER TOUTE GARANTIE OU CLAUSE IMPLICITE D...

Page 15: ...NOTES NOTAS NOTES...

Page 16: ...rk of 3M Company used under license 2011 3M Company All rights reserved INSTR2002 1111 3M Purification Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 222 7880 Worldwide 203 237 5541 Fax...

Reviews: