Parts and Materials Included:
1. Two Self-tapping Screws
2. Mounting
Bracket
3. Head
Assembly
4. Cartridge Model AP517
Tools and Parts Required (not included):
• Choice
of:
Two #10 Machine Screws (length to suit), Two Washers and
Two #10 Machine Screw Nuts
OR Two #10 Sheet Metal Screws and Two Washers
OR Two Wood Screws
• Two 3/8” MNPT x 3/8” or 1/2” Compression
Fittings Depending on Existing Plumbing
• PTFE
Tape
• Adjustable
Wrench
• Drill (Cordless Recommended)
• Phillips Head Screwdriver
• Razor Knife Or Tube Cutter
• 3/8” soft copper or plastic tubing, 5’ length
Empty contents of package and identify all parts as shown in
diagram. Read all instructions carefully before attempting to start
installation.
Before starting, close shut-off valve on kitchen
cold water line.
GETTING STARTED
1
2
4
3
Your new Aqua-Pure
®
AP510 Full Flow Drinking Water System will reduce chlorine tastes and odors, particulate and
scale from your drinking water. The filter installs under the sink on the cold water line and uses the existing faucet. The
AP510 features its own automatic shut-off, thereby eliminating the need for any external valves. The installation proce-
dure covered in this manual requires the removal of a section of the cold water tube. Soft copper tubing and compres-
sion fittings should be purchased locally to complete the installation.
1. Position the filter by holding it against the right hand side of the cabinet wall
underneath the sink. Allow at least 3” (7.6 cm) beneath the filter to install car-
tridge. Determine a desirable location for the filter installation and inlet connec-
tion. Attach the mounting bracket to appropriate mounting bosses on filter head
with the self-tapping screws supplied. (Figure 1)
2. For installation using machine screws and nuts, remove drawer from adjacent
cabinet and drill two 7/32” diameter holes through cabinet wall. Fasten filter
bracket to wall with screws, nuts and washers. Use washers on both sides of the
wall. Mounting to the cabinet side wall gives the filter good, rigid support. (Figure
2) For installation using sheet metal screws, simply prick punch at marked loca-
tion (Step 1), position bracket in place, and install screws with screwdriver.
IMPORTANT INSTALLATION INSTRUCTIONS
Figure 1
CAUTION
To reduce the risk associated with property damage due to water leakage:
•
Do not install on hot water supply lines
. The maximum operating water
temperature of this fi lter system is 100°F (37.8°C).
•
Do not
use a torch or other high temperature sources near fi lter system,
cartridges, plastic fi ttings or plastic plumbing.
IMPORTANT NOTES
• Allow a minimum of 3” (7.6 cm) clear space under fi lter to facilitate
cartridge change.
WARNING
To reduce the risk associated with a hazardous voltage due to an installer drill-
ing through existing electric wiring or water pipes in the area of installation:
•
Do not
install near electric wiring or piping which may be in the path of a
drilling tool when selecting the position to mount the fi lter bracket.
Figure 2
Note:
If the filter is not connected to the head assem-
bly upon opening this carton, please refer to the
“Filter Cartridge Replacement Instructions” Section,
Step 3.
Summary of Contents for Aqua-Pure AP510
Page 2: ......
Page 15: ...NOTES NOTAS NOTES...