61
Outlet Flow Characteristics
Manufacturers Minimum Design Flow (MMDF) 150 l/min
Manufacturers Maximum flow 230 l/min.
Battery Packs
4 Hour battery = 5.2V NiMH, Rechargeable
8 Hour battery = 5.2V NiMH, Rechargeable
I.S. battery = 7.8V NiMH, Rechargeable
Classification for use in Potentially Explosive atmospheres
Gas atmospheres (Gb)
EN 60079-11 Ex ib IIB T3 Gb
ib - intrinsic safety for Equipment protection level Gb.
IIB - Gas apparatus group (EN60079-0)
T3 - Max. surface temperature 200°C (Ta = -20°C to +40°C)
Dust atmospheres (Db)
EN 61241-1 Ex tb IIIC T55°C Db
tb - protection by enclosure for Equipment protection level Db.
IIIC - Dust apparatus groups (EN 60079-0)
T55°C - Max. surface temperature (Dust Zones)
SIRA Ex09Y2202X - Certification Number
New Comment: X - The battery must be charged in a safe area
Ingress Protection
Powered Air Turbo, EN60529 IP53
When fitted with I.S. pouch, EN60529 IP63
5x = Dust protection
6x = Dust tight
x3 = Spraying water
Operating Conditions
-5 to +40ºC and <90 % humidity
Weight (including 4 hour battery but excluding belt and filters)
Jupiter Powered Air Turbo = 815 grams