![3D Systems ProJet 1200 User Manual Download Page 43](http://html1.mh-extra.com/html/3d-systems/projet-1200/projet-1200_user-manual_442036043.webp)
38
3D Systems, Inc.
CLEANING THE UNIT
The internal parts of the build and curing chamber can be wiped clean with 70% isopropyl alcohol and a soft, non-scratching cloth,
(such as a microfiber). Make certain you inspect the glass that is a part of the print cartridge support. Remove the glass and clean any
resin, fingerprints or any other debris which may have accumulated.
Glass
Print Cartridge
Support
1 . Holding on to the bulb with tissue or paper towel, gently pull bulb down out of
socket (1) .
2 . After bulb is loose from socket, lift it out of the machine (2) .
3 . To replace the bulb, follow the procedure,
Installing the Curing Bulb
on page 14 .
1
2
Cleaning Cartridge Holder