Information Center Overview
455
■
With the UTC time zone, the time stamp is in the format of "Mmm dd
hh:mm:ss:ms yyyy [GMT +|- hh:mm:ss]".
Each field is described as follows:
■
"Mmm" represents the month, and the available values are: Jan, Feb, Mar, Apr,
May, Jun, Jul, Aug, Sep, Oct, Nov, and Dec.
■
"dd" is the date, which shall follow a space if less than 10, for example, " 7".
■
"hh:mm:ss:ms" is the local time, where "hh" is in the 24-hour format, ranging
from 00 to 23, both "mm" and "ss" range from 00 to 59, "ms" ranges from
000 to 999.
■
"yyyy" is the year.
■
"[GMT +|- hh:mm:ss]" is the UTC time zone, which represents the time
difference with the Greenwich standard time.
Because switches in a network may distribute in different time zones, when the
time displayed in the time stamps of output information is the local time on each
switch, it is not so convenient for you to locate and solve problems globally. In this
case, you can configure the information center to add UTC time zone to the time
stamp of the output information, so that you can know the standard time when
the information center processing each piece of information. That is, you can
know the Greenwich standard time of each switch in the network based on the
UTC record in the time stamp.
To add UTC time zone to the time stamp in the information center output
information, you must:
■
Set the local time zone
■
Set the time stamp format in the output direction of the information center to
date
■
Configure to add UTC time zone to the output information
After the above configuration, the UTC time zone will be displayed in the output
information, like the following:
%Dec 8 10:12:21:708 2006 [GMT+08:00:00] 4210 SHELL/5/LOGIN:- 1 -
VTY(1.1.0.2) in unit1 login
Sysname
Sysname is the system name of the local switch and defaults to "4210".
You can use the
sysname
command to modify the system name. Refer to
“Basic
System Configuration and Debugging” on page 483
.
Note that there is a space between the sysname and module fields.
Module
The module field represents the name of the module that generates system
information. You can enter the
info-center source ?
command in system view to
view the module list. Refer to Table 340 for module name and description.
Summary of Contents for Switch 4210 9-Port
Page 22: ...20 CHAPTER 1 CLI CONFIGURATION ...
Page 74: ...72 CHAPTER 3 CONFIGURATION FILE MANAGEMENT ...
Page 84: ...82 CHAPTER 5 VLAN CONFIGURATION ...
Page 96: ...94 CHAPTER 8 IP PERFORMANCE CONFIGURATION ...
Page 108: ...106 CHAPTER 9 PORT BASIC CONFIGURATION ...
Page 122: ...120 CHAPTER 11 PORT ISOLATION CONFIGURATION ...
Page 140: ...138 CHAPTER 13 MAC ADDRESS TABLE MANAGEMENT ...
Page 234: ...232 CHAPTER 17 802 1X CONFIGURATION ...
Page 246: ...244 CHAPTER 20 AAA OVERVIEW ...
Page 270: ...268 CHAPTER 21 AAA CONFIGURATION ...
Page 292: ...290 CHAPTER 26 DHCP BOOTP CLIENT CONFIGURATION ...
Page 318: ...316 CHAPTER 29 MIRRORING CONFIGURATION ...
Page 340: ...338 CHAPTER 30 CLUSTER ...
Page 362: ...360 CHAPTER 33 SNMP CONFIGURATION ...
Page 368: ...366 CHAPTER 34 RMON CONFIGURATION ...
Page 450: ...448 CHAPTER 39 TFTP CONFIGURATION ...
Page 451: ......
Page 452: ...450 CHAPTER 39 TFTP CONFIGURATION ...
Page 470: ...468 CHAPTER 40 INFORMATION CENTER ...
Page 496: ...494 CHAPTER 44 DEVICE MANAGEMENT ...