background image

 

F

 

ront Panel 

 

1

 

24 RJ45 Ports

 

WARNING:

 

 These are shielded RJ45 data sockets. They can not 

 

be used as telephone sockets. Only connect RJ45 data 

 

connectors to these sockets.

 

AVERTISSEMENT:

 

 Les ports RJ45 sont les prises de courant de 

 

données RJ45 protégées. Ils ne peuvent pas être utilisés comme 

 

prises de courant téléphoniques. Brancher seulement les 

 

connecteurs RJ45 de données à ces prises de courant.

 

WARNUNG:

 

 Hierbei handelt es sich um abgeschirmte RJ45 

 

Datenbuchsen, die nicht als Telefonbuchsen verwendbar sind. 

 

Nur RJ45 Datensteckverbinder an diese Buchsen anschließen.

 

These are shielded RJ45 data sockets. They can not be used as 

 

telephone sockets. Only connect RJ45 data connectors to these sockets.

 

Either shielded or unshielded data cables with shielded or unshielded 

 

jacks can be connected to these data sockets.

 

2

 

MDI Switch

 

The Media Dependent Interface (MDI) switch controls the operation of 

 

port 24. The switch is recessed and can be operated using a ball-point 

 

pen or similar instrument.

 

To form an inter-repeater link using two Hub 10 24 Port TPs, connect 

 

port 24 on unit 1 to any port on unit 2. Ensure that the MDI switch on 

 

unit 1 is IN (MDI) and that if port 24 is used on unit 2, the MDI switch is 

 

OUT (MDIX).

 

3

 

STATUS LEDs

 

The STATUS LEDs show the partition state of a port and whether or not 

 

the Link Pulse signal is present on the segment connected to a port:

 

If these checks do not identify the cause of a problem, it may be that the 

 

Hub 10 24 Port TP or the device connected to the port is faulty. Contact 

 

your supplier for further advice.

 

4

 

TCVR LED 

 

The TCVR LED lights red if the Transceiver Module port has partitioned. 

 

Refer to 

 

 

STATUS LEDs

 

 

 for information on what to do if a segment is 

 

partitioned.

 

A transceiver module port connected to coaxial cable segment 

 

may partition if the segment is incorrectly terminated.

 

The Transceiver Module port may partition if the SQE test pulse is 

 

enabled on its transceiver. SQE test should be disabled on transceivers 

 

used to connect 802.3 repeaters to the network.

 

5

 

AUI LED

 

The AUI LED lights red if the AUI port has partitioned. Refer to 

 

Status LEDs

 

 for information on what to do if a segment is partitioned.

 

An AUI port connected to coaxial cable segment may partition 

 

if the segment is incorrectly terminated.

 

The AUI port may partition if the SQE test pulse is enabled on its 

 

transceiver. SQE test should be disabled on transceivers used to connect 

 

802.3 repeaters to the network.

 

6

 

UNIT LEDs

 

The UNIT LEDs indicate the position of this unit in the stack, providing a 

 

Management Module or Advanced RMON Module has been fitted to a 

 

unit in the stack. The appropriate UNIT LED will light green; if this unit 

 

has a Management Module (or Advanced RMON Module) fitted, it will 

 

show as unit number 1. If the unit is in a stack which does not contain a 

 

Management Module or Advanced RMON Module, the UNIT LEDs will 

 

not light.

 

7

 

Packet LED

 

The Packet LED flashes yellow whenever a packet is received on one of 

 

the 24 twisted pair ports, the AUI port, or the Transceiver Module port.

 

If this LED does not flash, there are no packets being received by the 

 

unit.

 

8

 

Collision LED

 

The Collision LED flashes yellow when a packet collision has been 

 

detected on a segment connected to one of the 24 twisted pair ports, 

 

the AUI port, or the Transceiver Module port.

 

Under normal 802.3 operation, collisions occur and cause the Collision 

 

LED to flash. The probability of collisions increases during heavy activity 

 

on the network. The Auto Partition/Reconnection function partitions a 

 

segment from the rest of the network if more than 64 consecutive 

 

collisions are detected on that segment.

 

9

 

Power LED

 

The Power LED lights green to indicate the power supply to the unit is 

 

correct. If it is not lit, and:

 

10

 

MGMT LED

 

The MGMT LED indicates the status of the Management Module or 

 

Advanced RMON Module if fitted:

 

Out

 

In this position you can connect port 24 to a

 

workstation or any other DTE.

 

In

 

In this position you can connect port 24 to any 

 

internal cross-over (X) port on another 10Base-T 

 

repeater using normal twisted pair cable to form 

 

an inter-repeater link.

 

Green

 

The Link Pulse signal is being received and the segment 

 

attached to the port is functional. If the port does not 

 

transmit/receive, check the Disable On Boot switch 

 

15

 

 is 

 

Enabled.

 

Red

 

The Link Pulse signal is being received and the port is 

 

partitioned from the network.

 

Check the connections and the cable for any breaks in the 

 

segment.

 

Make sure the transceiver attached to the DTE is correctly 

 

connected and powered up.

 

Check for illegal 802.3 configurations, in particular, loops

 

Check that the Disable On Boot switch, 

 

15

 

, is set for units 

 

with standby ports in resilient links.

 

If the cause of the partition is found and corrected, the 

 

segment is reconnected automatically, after the first valid 

 

packet is transmitted to, or received from the segment.

 

Off

 

The Link Pulse signal is not being received.

 

Check that the attached DTE is switched on.

 

Check that the Link Pulse signal has not been disabled by 

 

management software.

 

Check that the attached transceiver is not faulty.

 

If it is port 24 or an inter-repeater link, check the setting of 

 

the MDI switch.

 

Carry out the checks recommended for when a STATUS 

 

LED is red.

 

Check for no more than 4 repeater stacks in series, and 

 

that cable lengths do not exceed the maximum specified 

 

in the standard for that medium.

 

None of the ports work

 

Check the fuse in the IEC socket and the 

 

fuse within the power cable's plug (if 

 

fitted).

 

The AUI and Transceiver 

 

Module ports do not work, 

 

but the twisted pair ports 

 

work

 

The internal fixed fuse for the power 

 

supply to the AUI and Transceiver 

 

Module ports has blown. Contact your 

 

supplier.

 

All ports function normally

 

The LED has failed. Contact your supplier.

 

Off

 

There is no Management Module or Advanced RMON 

 

Module fitted to the Hub 10 24 Port TP or the internal 

 

connection to it has been broken.

 

Green/(Yellow)

 

The Management Module (or Advanced RMON 

 

Module) is fitted and functioning normally.

 

Green flashing

 

Management agent software is being downloaded.

 

Red

 

There is a fault on the Management Module (or 

 

Advanced RMON Module) or one of the units in the 

 

stack. Check all connections and refer to the 

 

Management Module guide for more information.

i

MDIX

MDI

i

Summary of Contents for SUPERSTACK II HUB 10 24-PORT TP

Page 1: ...es must be used to ensure compliancewith these standards Environmental EN 60068 IEC 68 Width 440mm 17 3 ins Depth 224mm 8 8 ins Height 44mm 1 7 ins or 1U Weight 2 7kg 5 9lb Mounting free standing or 19 rack or wall mounted using kit supplied Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 28 VA Power Dissipation 96 BTU hr Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 36...

Page 2: ...e peut pas être mise en marche des sources de courant IT Impédance à la terre Si vos sources de courant sont de type IT cette unité doit être alimentée par 230V 2P T via un rapport de transformation d isolation de 1 1 avec un point de connexion secondaire étiqueté Neutre branché directement à la Terre à la Masse La Cordon d Alimentation Surmoulé Celui ci doit être approuvé pour le pays auquel il s...

Page 3: ... all TP ports on the unit will be disabled during power up until they are correctly configured and enabled by management software This is only necessary on units which have ports assigned as standby Standby ports in resilient link pairs can only be configured on SuperStack II Hub 10 or LinkBuilder FMS II units Security features are described in the manual which comes with your Hub 10 Management Mo...

Page 4: ... Module port If this LED does not flash there are no packets being received by the unit 8 Collision LED The Collision LED flashes yellow when a packet collision has been detected on a segment connected to one of the 24 twisted pair ports the AUI port or the Transceiver Module port Under normal 802 3 operation collisions occur and cause the Collision LED to flash The probability of collisions incre...

Page 5: ...ect units together Do not use two cables to connect any two units to each other they will not work if you do this Disconnect power from all units that will form part of the new stack Connect the male hub expansion connector of one unit to the female hub expansion connector of the next unit Repeat this process until all the units are connected together Refer to Stacking Units for the number of unit...

Page 6: ...etin Boards The upgrade includes instructions on how to load the agent Managing with an FMS Management Module Managing with a Hub 10 Management Module 3C16630A or a Hub 10 Advanced RMON Module 3C16632 If you have a Hub 10 LinkBuilder FMS or FMS II unit fitted with a Management Module and a LinkBuilder 10BTi in your stack the Hub 10 FMS or FMSII Management Module will manage the stack The LinkBuild...

Page 7: ...driver Repeat the last two steps for the other side of the units To wall mount the Hub 10 unit s Ensure that the wall you are going to use is smooth flat dry and sturdy Attach a piece of plywood 12 x 20 x 0 5 securely to the wall if necessary and mount the Hub 10 unit s as follows Position the unit s against the wall or plywood ensuring that the ventilation holes face sideways Mark on the wall the...

Page 8: ...N S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Limitation of Liability TO THE FULL EXTENT ALLOWED BY LAW 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL ...

Reviews: