Please read the following safety information carefully before 

 

installing the Hub 10 24 Port TP.

 

WARNING:

 

 Installation and removal of the unit must be 

 

carried out by 

 

qualified personnel only

 

.

 

Connect the unit to an earthed power supply to ensure 

 

compliance with safety standards.

 

It is essential that the socket outlet is installed near to the unit 

 

and is easily accessible. You can only disconnect the unit by 

 

removing the supply plug from the outlet.

 

This unit operates under SELV conditions (Safety Extra Low 

 

Voltage) according to IEC 950, the conditions of which are 

 

maintained only if the equipment to which it is connected is also 

 

operational under SELV.

 

The appliance coupler, i.e., the connector to the device itself and 

 

not the wall plug, must have a configuration for mating with an 

 

EN60320/IEC320 appliance inlet.

 

France and Peru Only

 

This unit cannot be powered from IT

 

 

 supplies. If your supplies are of IT 

 

type, this unit should be powered by 230V (2P+T) via an isolation 

 

transformer ratio 1:1, with the secondary connection point labelled 

 

Neutral, connected directly to Earth (Ground).

 

 

Impédance à la terre

 

Power Cord Set

 

This must be approved for the country where it will be used.

 

Veuillez lire à fond l'information de la sécurité suivante avant 

 

d'installer le Hub 10 24 Port TP.

 

AVERTISSEMENT:

 

 

 

L'installation et l'enlèvement de l'unité 

 

doivent être faits 

 

seulement par le personnel qualifié.

 

Brancher l'unité à une source de courant mise à la terre pour 

 

assurer la conformité aux normes de sécurité.

 

C'est essentiel que le socle soit installé près de l'unité et soit 

 

accessible.  Vous pouvez seulement débrancher l'unité en 

 

enlevant la fiche d'alimentation de la prise de courant.

 

Cette unité marche sous les conditions SELV (Safety Extra Low 

 

Voltage) conformément à IEC950, ces conditions sont maintenues 

 

seulement si le matériel auquel elle est branchée, est aussi en 

 

exploitation sous SELV.

 

Le socle de connecteur, c'est-à-dire, le connecteur à l'appareil 

 

lui-même et non pas la prise murale, doit avoir une configuration 

 

pour le branchement avec une admission d'appareil 

 

EN60320/IEC320.

 

Seulement Pour La France et Le Pérou

 

Cette unité ne peut pas être mise en marche des sources de courant IT 

 

(Impédance à la terre).  Si vos sources de courant sont de type IT, cette 

 

unité doit être alimentée par 230V (2P+T) via un rapport de 

 

transformation d'isolation de 1:1, avec un point de connexion secondaire 

 

étiqueté Neutre, branché directement à la Terre (à la Masse).

 

La Cordon d'Alimentation Surmoulé

 

Celui-ci doit être approuvé pour le pays auquel il sera utilisé.

 

Bitte unbedingt vor dem Einbauen des Hub 10 24 Port TP Einheit 

 

die folgenden Sicherheitsanweisungen durchlesen.

 

WARNUNG:

 

 Ein- und Ausbau des Gerätes ist 

 

nur von 

 

Fachpersonal

 

 vorzunehmen.

 

Das Gerät an geerdete Stromversorgung anschließen, um eine 

 

Übereinstimmung mit den Sicherheitsbestimmungen zu 

 

gewährleisten.

 

Es ist wichtig, daß der Netzstecker sich in unmittelbarer Nähe zum 

 

Gerät befindet und leicht erreichbar ist. Das Gerät kann nur durch 

 

Herausziehen des Verbindungssteckers aus der Steckdose vom 

 

Stromnetz getrennt werden.

 

Das Gerät wird mit Sicherheits-Kleinspannung nach IEC 950 (SELV 

 

= Safety Extra Low Voltage) betrieben. Angeschloßen werden 

 

k

 

ö

 

nnen nur Geräte, die ebenfalls nach SELV betrieben werden.

 

Die Anordnung der Gerätsteckvorrichtung, d.h. die 

 

Steckverbindung am Gerät selbst im Gegensatz zum Wandstecker, 

 

muß in den EN60320/IEC320 Zuführungsstecker am Gerät passen.

 

Der Anschlußkabelsatz muß mit den Bestimmungen des Landes 

 

übereinstimmen, in dem er verwendet werden soll.

S

AFETY

 I

NFORMATION

 

USA and 

 

Canada

 

The cord set must be UL-approved and CSA certified.

 

The minimum specifications for the flexible cord are:

 

No. 18 AWG

 

Type SV or SJ

 

3-conductor

 

The cord set must have a rated current capacity of at 

 

least 10A.

 

The attachment plug must be an earth-grounding 

 

type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P 

 

(15A, 250V) configuration.

 

Denmark

 

The supply plug must comply with Section 107-2-D1, 

 

Standard DK2-1a or DK2-5a.

 

Switzerland

 

The supply plug must comply with SEV/ASE 1011.

L’

INFORMATION

 

DE

 S

ÉCURITÉ

 I

MPORTANTE

 

USA et 

 

le 

 

Canada:

 

Le cordon surmoulé doit être UL Certifié et CSA Certifié.

 

Les spécifications minimales pour le cordon souple sont:

 

No. 18 AWG

 

Type 5V ou SJ

 

3-conducteur

 

Le cordon surmoulé doit avoir une capacité de courant 

 

calculée au moins de 10A.

 

La fiche de fixation doit être un type mis à la terre avec 

 

une configuration NEMA 5-15P (15A, 125V) ou NEMA 

 

6-15P (15A, 250V).

W

ICHTIGE

 S

ICHERHEITSINFORMATIONEN

Summary of Contents for SUPERSTACK II HUB 10 24-PORT TP

Page 1: ...es must be used to ensure compliancewith these standards Environmental EN 60068 IEC 68 Width 440mm 17 3 ins Depth 224mm 8 8 ins Height 44mm 1 7 ins or 1U Weight 2 7kg 5 9lb Mounting free standing or 19 rack or wall mounted using kit supplied Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 28 VA Power Dissipation 96 BTU hr Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 36...

Page 2: ...e peut pas être mise en marche des sources de courant IT Impédance à la terre Si vos sources de courant sont de type IT cette unité doit être alimentée par 230V 2P T via un rapport de transformation d isolation de 1 1 avec un point de connexion secondaire étiqueté Neutre branché directement à la Terre à la Masse La Cordon d Alimentation Surmoulé Celui ci doit être approuvé pour le pays auquel il s...

Page 3: ... all TP ports on the unit will be disabled during power up until they are correctly configured and enabled by management software This is only necessary on units which have ports assigned as standby Standby ports in resilient link pairs can only be configured on SuperStack II Hub 10 or LinkBuilder FMS II units Security features are described in the manual which comes with your Hub 10 Management Mo...

Page 4: ... Module port If this LED does not flash there are no packets being received by the unit 8 Collision LED The Collision LED flashes yellow when a packet collision has been detected on a segment connected to one of the 24 twisted pair ports the AUI port or the Transceiver Module port Under normal 802 3 operation collisions occur and cause the Collision LED to flash The probability of collisions incre...

Page 5: ...ect units together Do not use two cables to connect any two units to each other they will not work if you do this Disconnect power from all units that will form part of the new stack Connect the male hub expansion connector of one unit to the female hub expansion connector of the next unit Repeat this process until all the units are connected together Refer to Stacking Units for the number of unit...

Page 6: ...etin Boards The upgrade includes instructions on how to load the agent Managing with an FMS Management Module Managing with a Hub 10 Management Module 3C16630A or a Hub 10 Advanced RMON Module 3C16632 If you have a Hub 10 LinkBuilder FMS or FMS II unit fitted with a Management Module and a LinkBuilder 10BTi in your stack the Hub 10 FMS or FMSII Management Module will manage the stack The LinkBuild...

Page 7: ...driver Repeat the last two steps for the other side of the units To wall mount the Hub 10 unit s Ensure that the wall you are going to use is smooth flat dry and sturdy Attach a piece of plywood 12 x 20 x 0 5 securely to the wall if necessary and mount the Hub 10 unit s as follows Position the unit s against the wall or plywood ensuring that the ventilation holes face sideways Mark on the wall the...

Page 8: ...N S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Limitation of Liability TO THE FULL EXTENT ALLOWED BY LAW 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL ...

Reviews: