192
C
HAPTER
13: MSTP C
ONFIGURATION
4
Configure Switch D.
a
Enter MST region view.
<S5500> system-view
System View: return to User View with Ctrl+Z.
[S5500] stp region-configuration
b
Configure the MST region.
[S5500-mst-region] region-name example
[S5500-mst-region] instance 1 vlan 10
[S5500-mst-region] instance 3 vlan 30
[S5500-mst-region] instance 4 vlan 40
[S5500-mst-region] revision-level 0
c
Activate the settings of the MST region.
[S5500-mst-region] active region-configuration
BPDU Tunnel
Configuration
Example
Network requirements
■
Two Switch 5500 switches, Switch C and Switch D shown in Figure 46, operate as
the access devices of the operator’s network.
■
Two S2000 series switches, Switch A and Switch B shown in Figure 46, are used as
the access devices of the user network.
■
Switch C and Switch D are connected to each other through two ports that are
configured as trunk ports. The BPDU tunnel function is enabled in system view to
allow transparent transmission of BPDUs over the operator’s network.
Network diagram
Figure 46
Network diagram for BPDU tunnel configuration
Configuration procedure
1
Configure Switch A.
a
Enable RSTP.
<S5500> system-view
System View: return to User View with Ctrl+Z.
[S5500] stp enable
b
Add Ethernet0/1 port to VLAN 10.
[S5500] vlan 10
[S5500-Vlan10] port Ethernet 0/1
Summary of Contents for 5500 SI - Switch - Stackable
Page 24: ...24 ABOUT THIS GUIDE...
Page 50: ...50 CHAPTER 1 GETTING STARTED...
Page 54: ...54 CHAPTER 2 ADDRESS MANAGEMENT CONFIGURATION...
Page 78: ...78 CHAPTER 3 PORT OPERATION...
Page 88: ...88 CHAPTER 4 XRN CONFIGURATION...
Page 122: ...122 CHAPTER 8 VLAN VPN CONFIGURATION...
Page 216: ...216 CHAPTER 15 SSH TERMINAL SERVICES...
Page 268: ...268 CHAPTER 16 IP ROUTING PROTOCOL OPERATION...
Page 308: ...308 CHAPTER 17 NETWORK PROTOCOL OPERATION...
Page 349: ...349...
Page 350: ...350 CHAPTER 18 MULTICAST PROTOCOL...
Page 522: ...522 CHAPTER 22 FILE SYSTEM MANAGEMENT...
Page 584: ...584 CHAPTER 30 PASSWORD CONTROL CONFIGURATION OPERATIONS...
Page 600: ...600 CHAPTER 31 MSDP CONFIGURATION...
Page 614: ...614 CHAPTER 32 CLUSTERING...
Page 670: ...670 CHAPTER C AUTHENTICATING THE SWITCH 5500 WITH CISCO SECURE ACS...