482
C
HAPTER
22: F
ILE
S
YSTEM
M
ANAGEMENT
modu-name
specifies the module name;
default
represents all the modules;
level
refers to the severity levels;
severity
specifies the severity level of information. The
information with the level below it will not be output.
channel-number
specifies the
channel number and
channel-name
specifies the channel name.
When defining the information sent to the trap buffer,
channel-number
or
channel-name
must be set to the channel that corresponds to the Console direction.
Every channel has been set with a default record, whose module name is
default
and the module number is 0xffff0000. However, for different channels, the default
record may have different default settings of log, trap and debugging. When there is
no specific configuration record for a module in the channel, use the default one.
If you want to view the debugging information of some modules on the Switch, you
must select
debugging
as the information type when configuring information source,
meantime using the
debugging
command to turn on the debugging Switch of those
modules.
You can use the following commands to configure log information, debugging
information and the time-stamp output format of trap information.
Perform the following operation in System View.
Table 550
Configuring the Output Format of Time-stamp
Sending the Information
to SNMP Network
Management
To send information to SNMP NM, follow the steps below:
1
Enabling info-center
Perform the following operation in System View.
Table 551
Enabling/Disabling Info-center
Info-center is enabled by default. After info-center is enabled, system performances
are affected when the system processes much information because of information
classification and outputting.
2
Configuring to output information to SNMP NM
Perform the following operation in System View.
Table 552
Configuring to Output Information to SNMP NM
Operation
Command
Configure the output format of
the time-stamp
info-center timestamp { log | trap |
debugging } { boot | date | none }
Output time-stamp is disabled
undo info-center timestamp { log | trap |
debugging }
Operation
Command
Enable info-center
info-center enable
Disable info-center
undo info-center enable
Operation
Command
Output information to SNMP NM
info-center snmp channel {
channel-number
|
channel-name
}
Cancel the configuration of outputting
information to SNMP NM
undo info-center snmp channel
Summary of Contents for 5500 SI - Switch - Stackable
Page 24: ...24 ABOUT THIS GUIDE...
Page 50: ...50 CHAPTER 1 GETTING STARTED...
Page 54: ...54 CHAPTER 2 ADDRESS MANAGEMENT CONFIGURATION...
Page 78: ...78 CHAPTER 3 PORT OPERATION...
Page 88: ...88 CHAPTER 4 XRN CONFIGURATION...
Page 122: ...122 CHAPTER 8 VLAN VPN CONFIGURATION...
Page 216: ...216 CHAPTER 15 SSH TERMINAL SERVICES...
Page 268: ...268 CHAPTER 16 IP ROUTING PROTOCOL OPERATION...
Page 308: ...308 CHAPTER 17 NETWORK PROTOCOL OPERATION...
Page 349: ...349...
Page 350: ...350 CHAPTER 18 MULTICAST PROTOCOL...
Page 522: ...522 CHAPTER 22 FILE SYSTEM MANAGEMENT...
Page 584: ...584 CHAPTER 30 PASSWORD CONTROL CONFIGURATION OPERATIONS...
Page 600: ...600 CHAPTER 31 MSDP CONFIGURATION...
Page 614: ...614 CHAPTER 32 CLUSTERING...
Page 670: ...670 CHAPTER C AUTHENTICATING THE SWITCH 5500 WITH CISCO SECURE ACS...