222
C
HAPTER
18: M
ANAGING
D
EVICE
D
IAGNOSTICS
To test cables:
1
Click
Monitoring > Cable Diagnostics > Diagnostics
. The
Diagnostics
Page
opens:
Figure 114
Diagnostics Page
The
Diagnostics Page
contains the following fields:
■
Select a Port
— Selects the port to be tested.
■
Test Result
— Displays the cable test results. Possible values are:
■
OK
— Indicates that the cable passed the test.
■
Failed
— Indicates that the cable failed the test. The test will fail if a
cable is not connected to the port, the cable is connected on only
one side, the cable is shorter than one meter, or a short has
occurred in the cable.
■
Cable Fault Distance
— Indicates the distance in meters from the
port where the cable error occurred.
A Cable Fault Distance of 0M can result from a short (< 1 meter) cable, an
open cable or a 2-pair copper cable.
■
Last Update
— Indicates the last time the port was tested.
2
Select a port to be tested. The port is tested, and the page is updated.
Summary of Contents for 3CRDSF9PWR-US - OfficeConnect Managed Fast Ethernet PoE Switch
Page 6: ...6 ABOUT THIS GUIDE ...
Page 14: ......
Page 102: ...102 CHAPTER 4 MANAGING DEVICE SECURITY ...
Page 112: ...112 CHAPTER 5 MANAGING SYSTEM INFORMATION ...
Page 120: ...120 CHAPTER 6 CONFIGURING PORTS ...
Page 140: ...140 CHAPTER 8 CONFIGURING VLANS ...
Page 198: ...198 CHAPTER 14 MANAGING SYSTEM FILES ...
Page 204: ...204 CHAPTER 15 MANAGING POWER OVER ETHERNET DEVICES ...
Page 228: ...228 APPENDIX A 3COM NETWORK MANAGEMENT ...
Page 234: ...234 APPENDIX B DEVICE SPECIFICATIONS AND FEATURES ...
Page 238: ...238 APPENDIX C PIN OUTS ...
Page 256: ......